Concerns about the impact on the environment of the refrigerants used in HVAC&R equipment are driving the development of alternative refrigerants with lower global warming potentials (GWPs). This paper reports the performance of DR-55 (now designated as R452B), DR-5A (now designated as R454B), and R32 in comparison to R410A at the component level from tests run on a 4 RT (14 kW) commercial unitary rooftop heat pump. Overall unit performance was previously reported (Schultz and Kujak, 2016), showing DR-55 and DR-5A to be design-compatible replacement candidates for R410A. This paper further confirms this by comparing performance at the compressor, evaporator, and condenser component level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of R410A and R22 Low GWP Alternative Refrigerants at Elevated Ambient Temperatures

Growing concerns about the global warming impact of refrigerants used in HVAC&R equipment are driving development and evaluation of alternative refrigerants with lower global warming potentials (GWPs). The Air Conditioning, Heating, and Refrigeration Institute (AHRI) recently coordinated the Low-GWP Alternative Refrigerant Evaluation Program (AREP) in which commercial, university, and governmen...

متن کامل

Performance Measurement of R32 in Vapor Injection Heat Pump System

As global warming has raised more critical concerns in recent years, refrigerants with high global warming potentials (GWP) are facing the challenges of being phased out. R410A, with a GWP of 2,088, has been widely used in residential air-conditioning and heat pump systems. A potential substitute for R410A is R32, which has a GWP of 675. This paper investigates the performance difference of R41...

متن کامل

Performance Measurement of R32 Vapor Injection Heat Pump System

As global warming has raised more critical concerns in recent years, refrigerants with high global warming potentials (GWP) are facing the challenges of being phased out. R410A, with a GWP of 2,088, has been widely used in residential air-conditioning and heat pump systems. A potential substitute for R410A is R32, which has a GWP of 675. This paper investigates the performance difference of R41...

متن کامل

Development of Polyol Ester Refrigeration Oils for HFO Refrigerants

Recently, R32 refrigerant, which has low global warming potential (GWP), attracts much attention as an alternative one instead of R410A and has started to be used in practical systems of room air conditioners (RAC), but compared with natural refrigerants, its GWP of 675 is still high and it is required to use refrigerants with much lower GWP. In addition, although R134a (GWP=1300) is widely use...

متن کامل

Investigation of Vapor Injection Heat Pump System with a Flash

Title of Dissertation: INVESTIGATION OF VAPOR INJECTION HEAT PUMP SYSTEM WITH A FLASH TANK UTILIZING R410A AND LOW-GWP REFRIGERANT R32 Xing Xu, Doctor of Philosophy, 2012 Dissertation Directed by: Professor Reinhard Radermacher Department of Mechanical Engineering Vapor injection technique has proven to be effective in improving heat pump system performance, especially for cooling application a...