Direct measurement of mucosal pressures exerted by cuff and non-cuff portions of tracheal tubes with different cuff volumes and head and neck positions.
نویسندگان
چکیده
We measured directly mucosal pressures against the cuff and non-cuff portions of the tracheal tube in different head-neck positions and tested the reliability of calculated mucosal pressures, in vivo intracuff pressures and cuff volume as determinants of directly measured mucosal pressures. We studied 10 anaesthetized, paralysed adult patients. An 8.5-mm, high volume, low pressure PVC tracheal tube was used. Microchip sensors were attached to three cuff locations (anterior, lateral and posterior) and two non-cuff locations (anterior tip and anterior aspect of the tube, 5 cm proximal to the cuff). Directly measured mucosal pressures, in vivo intracuff pressures and calculated mucosal pressures (in vivo minus in vitro intracuff pressures) were determined after brief inflation (< 15 s) to 0, 5, 10 and 15 ml. In vivo intracuff pressures were then set at 30 mm Hg and the measurements repeated, first in the neutral position and then with the head-neck extended, flexed and rotated. Cuff mucosal pressures were highest anteriorly and lowest posteriorly. Non-cuff mucosal pressures did not vary with cuff volume and were approximately 15 mm Hg. Compared with the neutral position, in vivo intracuff pressures were higher in the rotated, extended and flexed positions. Compared with the neutral position, mucosal pressure increased on the anterior aspect of the tube in the flexed position by 22 mm Hg (P = 0.003), at the anterior tip in the extended position by 11 mm Hg (P = 0.002) and at the anterior tip (5 mm Hg, P = 0.05) and lateral aspect of the cuff (5 mm Hg, P = 0.03) in the rotated position. In vivo intracuff pressures and calculated mucosal pressures were moderate predictors of measured mucosal pressures; cuff volume was a poor predictor. We conclude that tracheal mucosal pressures were highest anteriorly, that non-cuff portions of the tube exerted substantial mucosal pressures and that the rotated position caused a greater increase in tracheal mucosal pressure than the extended or flexed position. Indirect methods of measuring mucosal pressure were of moderate predictive value.
منابع مشابه
Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level
Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...
متن کاملTHE EFFECT OF CHANGE IN POSITION ON INTRATRACHEAL CUFF PRESSURE IN PATIENTS UNDERGOING SURGERY WITH GENERAL ANESTHESIA: A PROSPECTIVE ANALYTICAL STUDY
Background & Aims: Tracheal intubation with a cuffed tube for the administration of general anesthesia is routine. The cuff of the endotracheal tube is inflated with air to achieve an adequate seal to prevent aspiration and leakage of air and anesthetic gases. Whereas over-inflation can decrease the mucosal perfusion, leading to pressure necrosis and nerve palsies. This study aimed to evaluate ...
متن کاملComparison of mucosal pressures induced by cuffs of different airway devices.
BACKGROUND High pressures exerted by balloons and cuffs of conventional endotracheal tubes, the Combitube (Tyco Healthcare Nellcor Mallinckrodt, Pleasanton, CA), the EasyTube (Teleflex Ruesch, Kernen, Germany), the Laryngeal Mask Airway (LMA North America, San Diego, CA), the Intubating Laryngeal Mask Airway (Fastrach; LMA North America), the ProSeal (LMA North America), and the Laryngeal Tube ...
متن کاملبررسی تاثیر تغییر وضعیت بدن بر فشار کاف لوله تراشه در بیماران تحت تهویه مکانیکی
Background: Endotracheal tube cuff pressure must be maintained in safe range. Many factors could be affecting on endotracheal tube cuff pressure in patients on mechanical ventilation. Patients undergoing mechanical ventilation (MV) in critical care settings require changing position for different reasons. The aim of this study was to determine the effect of changes in body position and head of ...
متن کاملComparison of Pressure Changes by Head and Neck Position between High-Volume Low-Pressure and Taper-Shaped Cuffs: A Randomized Controlled Trial
The present study compared changes in cuff pressure by head and neck position between high-volume low-pressure (HVLP) and taper-shaped (taper) cuffs in a prospective randomized clinical trial. Methods. Forty patients were intubated using tracheal tubes with either HVLP (n = 20; HVLP group) or taper-shaped (n = 20; Taper group) cuffs. Initial cuff pressure was adjusted to 15, 20, or 25 cmH2O in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 82 5 شماره
صفحات -
تاریخ انتشار 1999