Improvement in XAFS beamline BL01B1 at SPring-8
نویسندگان
چکیده
Beamline BL01B1 was constructed for conventional XAFS measurements using a bending magnet light source at SPring-8 in 1997 [1]. BL01B1 covers a wide energy range from 3.8 to 113 keV using an adjustable inclined double-crystal monochromator and a double mirror system. Here, we describe a newly developed apparatus and the current status of the BL01B1. A time-efficient QEXAFS method was developed to measure high quality spectra up to high-k regions in the shortest possible time. The method involves sweeping the monochromator continuously at a variable angular speed depending on the k-region using a VME stepping motor controller. During scanning, a pair of crystals of the monochromator rotates without translation motion like a channel-cut crystal. This QEXAFS method was applied to the fluorescence mode using a 19-element Ge detector combined with a digital X-ray processor system. A new conversion electron yield detector having a rotational sample stage was developed for single crystalline samples. Angular oscillations of 4 degrees in the sample rotation stage around the axis normal to the sample surface successfully remove diffraction noise in the XAFS spectra.
منابع مشابه
XAFS analysis of triiodide ion in solutions.
Iodine K-edge XAFS of triiodide ions in various solvents were measured at SPring-8 BL01B1 and analyzed. Though the anion takes a linear and symmetric form, the second peak expected from enhanced multiple scatterings can be hardly observed because of its large vibrations. The bond distances and the Debye-Waller factors for the I-I couple vary when protic solvents were used and they were similar ...
متن کاملNew XAFS beamline for structural and electronic dynamics of nanoparticle catalysts in fuel cells under operating conditions
We are currently constructing a new X-ray absorption fine structure (XAFS) beamline BL36XU at SPring-8 dedicated for the structural and electronic analysis of the dynamic events on polymer electrolyte fuel cell (PEFC) cathode catalysts for the development of next-generation PEFCs. To investigate the cathode catalyst nanoparticles in PEFCs under the operating conditions, the beamline is designed...
متن کاملDetermination of Chemical States of Mercury on Activated Carbon Using XANES
Although the adsorption of mercury vapor onto activated carbon is a widely used technology to prevent environmental release, the adsorption mechanism is not clearly understood. In this study, we determined the chemical states of mercury on two kinds of activated carbon using X-ray absorption near-edge spectroscopy (XANES) to elucidate the adsorption mechanism. The adsorption experiments of elem...
متن کاملA New XAFS Beamline NW10A at the Photon Factory
A new XAFS beamline NW10A using bending magnet radiation from 6.5 GeV PF-AR has been constructed. NW10A consists of a Si(311) double crystal monochromator and a Pt-coated bent cylindrical focusing mirror and provides focused X-ray beam between 8 and 42 keV. The obtained flux through a 1mm square slit is 1×10 ph/s at 20 keV and 7×10 ph/s at 30keV, which are 20 and 200 times more intense than obt...
متن کاملSPring-8 BL36XU: Catalytic Reaction Dynamics for Fuel Cells
A tapered undulator beamline BL36XU was constructed at SPring-8 to conduct structural and electronic analysis of dynamic events on polymer electrolyte fuel cell (PEFC) cathode catalysts for the development of next-generation PEFCs. BL36XU provides various time and spatially resolved XAFS techniques in an energy range from 4.5 to 35 keV for investigating PEFCs under the operating conditions. In ...
متن کامل