Effect of simulated microwave disinfection on the mechanical properties of three different types of denture base resins.

نویسندگان

  • Jagadish Konchada
  • Suma Karthigeyan
  • Syed Asharaf Ali
  • Venkateshwaran R
  • Ramesh Amirisetty
  • Anurag Dani
چکیده

STATEMENT OF PROBLEM Disinfection of prostheses with chemical solutions has deleterious effects on dentures. The appropriate power setting of microwave for disinfection, without affecting denture base properties, is a controversy. PURPOSE To evaluate and compare the effect of simulated microwave disinfection at a recommended power setting on the mechanical properties of three denture base heat polymerized acrylic resins. MATERIAL AND METHODS Ninety rectangular specimens of each acrylic resin of 65mm × 10mm × 3 mm dimensions were divided into three groups. Group A (Trevalon), Group B (Trevalon- HI), Group C (Ivocap). In each group, thirty specimens were divided into three subgroups with ten specimens in each and they were submitted to MicroVickers hardness, flexural strength, and impact strength tests. In each subgroup, five specimens were tested before the simulated microwave disinfection and they served as the control group. The remaining five were tested after simulated microwave disinfection and they were considered as the experimental group. Simulated microwave disinfection was done in a domestic microwave oven at 650 W for 5 minutes. RESULTS The data were analyzed using One-way ANOVA and t-test. The mechanical properties of the three denture base resins were not altered after simulated microwave disinfection, as compared to those of the controls. CONCLUSION Microwave irradiation at 650 W for 5 min did not affect the mechanical properties of the three denture base resins. Domestic microwave oven, at the prescribed setting, can be used as an alternative method of disinfection for complete dentures without affecting their properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins.

The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions...

متن کامل

Silver nanoparticle incorporation effect on mechanical and thermal properties of denture base acrylic resins

Objective The aim of the present study was to evaluate the mechanical and thermal characteristics of two denture base acrylic resins containing silver nanoparticles (AgNPs). Material and Methods Two different acrylic denture base resins (heat-polymerized and microwave polymerized) containing 0.3, 0.8 and 1.6 wt% AgNPs were evaluated for flexural strength, elastic modulus and impact strength. ...

متن کامل

بررسی میزان چسبندگی کاندیدا آلبیکنس به مواد مورد استفاده در ساخت بیس دنچرهای متحرک

Statement of Problem:The surface topography of denture base material is an important factor for the adhesion of Candida albicans and other microorganisms.Purpose: The aim of this study was to evaluate the adherence of Candida albicans to four types of denture base materials (Acropars acrylic resin, Meliodent acrylic resin, rough and smooth surfaces of Molloplast B).Materials and Methods: Seven ...

متن کامل

Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation. Surface roughness of denture base and reline materials

OBJECTIVE The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Trusoft-T; Sofreliner-S, Dentusil-D) was evaluated. MATERIAL AND METHODS Thirty specimens of each mat...

متن کامل

Effect of microwave disinfection on denture base adaptation and resin surface roughness.

This study evaluated the effect of disinfection methods [chemical disinfection (immersion in 100 ppm chloride solution) or microwave disinfection (690 W for 6 min)] on the internal adaptation of denture bases and resin surface roughness. For the adaptation test, 18 maxillary denture bases were obtained from stone casts duplicated from a metallic master model and submitted to the following treat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical and diagnostic research : JCDR

دوره 7 12  شماره 

صفحات  -

تاریخ انتشار 2013