Fungal spore transport through a building structure.

نویسندگان

  • M Airaksinen
  • J Kurnitski
  • P Pasanen
  • O Seppänen
چکیده

The study carried out laboratory measurements with a full-scale timber frame structure to determine penetration of inert particles with size distribution from 0.6 to 4 microm and spores of Penicillium and Cladosporium through the structure. Pressure difference over and air leakage through the structure were varied. Measurements at moderate pressure differences resulted in the penetration factors within the range of 0.05-0.2 for inert particles, and indicated also the penetration of fungal spores through the structure. The measurements showed that the penetration was highly dependent on pressure difference over the structure but not on holes in surface boards of the structure. The results show that surface contacts between the frames and mineral wool may have a significant effect on penetration. The penetration was approximately constant within particle size rage of 0.6-2.5 microm, but particles with diameter of 4.0 microm did not penetrate through the structure at all even at a higher-pressure difference of 20 Pa, except in the case of direct flow-path through the structure. Results have important consequences for practical design showing that penetration of fungal spores through the building envelope is difficult to prevent by sealing. The only effective way to prevent penetration seems to be balancing or pressurizing the building. In cold climates, moisture condensation risk should be taken into account if pressure is higher indoors than outdoors. Determined penetration factors were highly dependent on the pressure difference. Mechanical exhaust ventilation needs a special consideration as de-pressurizing the building may cause health risk if there is hazardous contamination in the building envelope exists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-Seasonal Variation of Airborne Aspergillus Spore Concentration in a Hospital Building.

Nosocomial fungal infections are gaining increased attention from infectiologists. An adequate investigation into the levels of airborne Aspergillus and other fungal spores in hospital settings, under normal conditions, is largely unknown. We monitored airborne spore contamination in a Swiss hospital building in order to establish a seasonally-dependent base-line level. Air was sampled using an...

متن کامل

Does Specific Fungal Allergen Really Matter?

389 Exposure and sensitization to allergens can promote development and exacerbation of allergic disease. Various indoor aller-gens, including dust mites, animal dander, and mold have been reported to associate with allergic disease. Fungal spores and particles are widely distributed in outdoor and indoor environments and exposure to fungi has been shown to induce allergic disease and exacerbat...

متن کامل

Preliminary studies on the effect of the Burkard alternate orifice on airborne fungal spore concentrations

The Burkard 7-day spore trap with standard orifice is commonly used by researchers in sampling outdoor air. The alternate orifice is reported to have higher efficiency in collecting small airborne fungal spores; however, no previous studies compared Burkard samplers with different orifices. This study was conducted to study the effect of the alternate orifice on the concentration of airborne fu...

متن کامل

Relationships Between land Use and Arbuscular Mycorrhizal (AM) Spore Abundance in Calcareous Soils

This study was conducted to determine soil properties that correlate with the arbuscular mycorrhizal fungal (AMF) spore numbers in semiarid calcareous soils of Hamadan province in northwestern of Iran. Soil samples from six sites managed differently were collected from a 0 to 30 cm depth. The results showed that land use and management systems had a significant effect on AMF spore number in soi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 2004