Comparison of inferior dental nerve block injections in child patients using 30-gauge and 25-gauge short needles.

نویسندگان

  • J W Brownbill
  • P O Walker
  • B D Bourcy
  • K M Keenan
چکیده

Thirty-gauge needles are generally not recommended by dental schools, yet many dentists use them. Thin needles (30 gauge) can aspirate blood, have similar deflection to thick needles (25 gauge), and resist breakage. Measurable clinical differences between inferior dental block injections using 25-gauge or 30-gauge short needles for children is addressed in this research paper. Random allocation assigned 76 cases to 30-gauge and 62 cases to 25-gauge tribeveled. Twenty-seven-gauge short needles are in routine use for inferior dental nerve block injections in our clinics. After informed written consent was obtained, inferior dental block injections were carefully administered to children (62 males and 76 females, mean age 10 years ± 3 [SD], range 4-18 years) by faculty and students in pediatric dentistry and observed by one of two trained observers. After aspiration in two planes (180°), 0.5 mL of 2% lidocaine with 1:100,000 epinephrine was deposited in the lingual block area then 1.0 mL in the inferior dental area after touching bone. Any aspirate was recorded and subjective pain scores were taken immediately using a visual analogue scale. Five minutes after the commencement of the injection, the efficacy was tested objectively by two light needle pricks of the mucosa adjacent to the cuspid. The comparability of groups as regards age and sex was verified. Half of the injections were effective at five minutes in each group. There were no significant differences in efficacy, or pain scores. Both 25- and 30-gauge groups had nine instances of slight aspiration and two instances of more marked aspirations. The overall aspiration rate was 16%. It is concluded that 25- and 30-gauge needles do not differ significantly with respect to efficacy, pain, or aspiration. Children do not think that inferior dental nerve block injections hurt very much, and there is no evidence to support a change from 25- to 30-gauge needles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Inferior Dental Nerve Block Injections in Child Patients Using 30-Gauge and 27-Gauge Short Needles

Introduction: The purpose of the present study was to record their pain sensation and to assess children`s reaction objectively and subjectively while receiving dental local anesthesia with 27- and 30-gauge needles. Methods: Forty children (24 boys and 16 girls) participated in this study. A random double-blinded crossover design was used so that each child served as his or her own control, rec...

متن کامل

Size doesn't matter: needle gauge and injection pain.

Many dentists prefer using smaller gauge (27- or 30-gauge) needles for anesthesia injection, believing that needles with a smaller diameter result in less injection pain than wider diameter needles. For this study, three dentists in a general practice administered 930 injections to 810 adult patients using 25- and 27-gauge needles for mandibular inferior alveolar block injections and 25-, 27-, ...

متن کامل

Comparative study of two needle models in terms of deflection during inferior alveolar nerve block.

OBJECTIVES The purpose of this study is to determine the possible differences in deflection between two needles of same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The initial working hypothesis was that greater deflection may be expected with larger internal gauge needles. STUDY DESIGN Four clinicians subjected 346 patient...

متن کامل

The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection

BACKGROUND AND AIMS Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity,...

متن کامل

Comparison of a New Auto-controlled Injection System with Traditional Syringe for Mandibular Infiltrations in Children: A Randomized Clinical Trial

BACKGROUND Pain in the dental operatory can have a profound effect on the behavior of children. AIM The aim of this study is to evaluate the pain perception while administering local infiltration, in children undergoing dental extractions, using a new auto-controlled injection system. MATERIALS AND METHODS Children in the age range of 6-10 years with teeth indicated for extraction were recr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia progress

دوره 34 6  شماره 

صفحات  -

تاریخ انتشار 1987