New Anatomical Landmark for Surgical Release of A1 Pulley in the Hand

نویسنده

  • Yolchai Jongjirasiri
چکیده

Anatomical landmark of A1 pulley is important especially in minimal invasive surgery. The lengths and landmarks of A1 pulleys were evaluated in 510 preserved cadaver digits. The cadavers were 25 females and 26 males aged at the time of death ranged from 48 to 89 years. Measurements of A1 pulley lengths were made and used to predict the landmarks of the proximal pulley margins, which are related to the knuckle via an imaginary perpendicular line to the palmar surface of the fingers and thumbs in an objective way. The average lengths of the A1 pulleys in each digit were as follows: thumb;5.30 ± 0.53, index finger; 6.32 ± 0.17, middle finger; 6.58 ± 0.19, ring finger; 6.32 ± 0.19, and little finger 5.30 ± 0.49 mm. The average lengths of all fingers were 6.13 ± 0.57 mm. The margin from the proximal edge of the A1 pulleys on the perpendicular line from the knuckle to the palm was in the same line in 327 (64.1% ) fingers and thumbs, while 464 (91.0 %) fingers and thumbs were ≤ 1 mm and 509 ( 99.8 %) were ≤ 2mm to the proximal edge of the A1 pulley of its finger or thumb. In conclusion, the tip of the knuckle line perpendicular to each digit was a new surface anatomical landmark that was useful for identifying the proximal part of A1 pulley during the operative procedure. INTRODUCTION Knowledge regarding surface landmarks of A1 pulleys is important to surgical treatment of trigger digit especially in minimal invasive and percutaneous techniques. 1,2 One popular technique of percutaneous release of trigger digit was described by Jean Lorthioir who used the palmar crease as a landmark for localizing A1 pulleys. 2 However, this technique can be inaccurate due to the variability of palmar creases or hand size. 1,3,4 Wilhelmi et al. found that the distance from the palmar digital crease to the proximal interphalangeal crease corresponded to the distance of the proximal edge of the A1 pulley to the palmar digital crease. 1, 5 In addition, none of the several anatomic studies of the A1 pulley has been described the location of the A1 pulley in relation to the knuckle. 6-11 The purpose of this study was to measure the length of the A1 pulley in each digit and revealed the landmark of the proximal edge of the A1 pulley with relation to knuckle line in perpendicular line to the palm of its finger and thumb. MATERIALS AND METHODS Five hundred and ten preserved cadaver digits were dissected with a 4X loupe for measurement of length and landmark of A1 pulley by using a caliper of 1 orthopedist. Measurements were also taken of the proximal A1 pulley margins relating the central tip of the knuckle which was lined perpendicular to the palm. The distance between the proximal edge of the A1 pulley and the perpendicular line from the knuckle to the palm of each digit was measured, by using a large reduction with point which one point was fixed to the center of the knuckle griped over the palm and the other to the flexor tendon while the hand was placed over the table with both the shaft and the handle of reduction with point perpendicular to the palm. Each distance was measured twice. Fig.1.Landmarks for measurements of proximal A1 pulley margins with relation to the central tip of knuckle which lined up perpendicular to palm.(A) And the distance from the proximal edge of the A1 pulley (B) to the perpendicular line from the knuckle to the palm of each fingers (left) and thumbs (right) was measured Fig. 2.The distance of knuckle line (A) and the proximal edge of A1 pulley (B) was measured of index finger (left) and thumb (right) Fig.3. Demonstration measurement technique using vernier of the A1 pulley of middle finger (left) and thumb (right). Table1. Measurements of the distance from the proximal edge of the A1 pulley to the perpendicular line from the knuckle to the palm of each finger and thumb Digit Same line (digit) % ≤ 1 mm (digit) % ≤2 mm (digit) % Thumb 67 65.70 95 93.10 102 100 Index 59 57.80 91 89.20 102 100 Middle 62 60.80 90 88.20 102 100 Ring 69 67.60 94 92.20 102 100 Little 70 68.60 94 92.20 101 99.0 Average of all digits 327 64.10 464 91.00 509 99.8 Table2. The length of A1 pulleys Digit Length of A1 pulley (mm) Maximum Minimum Mean SD Thumb 4.4 6.50 5.30 0.53 Index 6.0 6.75 6.32 0.17 Middle 6.0 7.00 6.58 0.19 Ring 6.0 6.80 6.32 0.20 Little 4.1 6.40 5.30 0.49 Average of all digits 5.8 6.46 6.13 0.17 RESULTS In the 510 cadaveric digit dissections, the margin from the proximal edge of the A1 pulley to the perpendicular line from the knuckle to the palm was in the same line in 327 digits (64.10%), was ≤ 1 mm in 464 (91.0%), and ≤ 2mm in 509 (99.80%). The overall mean difference was 0.37 ± 0.55 mm. The margin from the proximal edge of the A1 pulleys of the thumb, index, middle, ring and little finger were 67(65.70 %), 59(57.80 %), 62(60.80 %), 69(67.60 %), 70(68.60 %) digits respectively to the same line in the perpendicular line from the knuckle to the palm. The margin from the proximal edge of the A1 pulleys of the thumb was 67 (65.70 %) digits as same line as in the perpendicular line from the knuckle to the palm. The thumb, index, middle, ring and little finger were 95(93.10 %),91(89.20%),90( 88.20%), 94(92.20 %),94( 92.20 %) digits respectively differences ≤ 1 mm to the line in the perpendicular line from the knuckle to the palm (Table 1). The length of A1 pulley averaged 5.30 ± 0.53 mm for thumb, 6.32 ± 0.17 mm for index, 6.58 ± 0.19 mm for middle, 6.32 ± 0.19 mm for ring, and 5.30 ± 0.49 mm for small finger, whereas the A1 pulley of small fingers were not significantly shorter (p>0.05) than the length of the A1 pulley for the index, middle and ring fingers with a 95 percent confidence interval (Table 2).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Length and landmark of A1 pulley in hand: an anatomical study.

OBJECTIVE The purpose of the present study was to identify length and landmark of proximal of A1 pulley in hand. MATERIAL AND METHOD An anatomical study of the length and landmark of A1 pulley in hand was performed in 510 fingers and thumbs from 51 preserved cadavers. There were 25 females and 26 males whose ages at the time of death ranged from 48 to 89 years. RESULTS The lengths of A1 pul...

متن کامل

Percutaneous release of the A1 pulley: a cadaver study.

PURPOSE Percutaneous release of the A1 pulley has been used for treatment of trigger fingers with success. However, lack of direct visualization raises concerns about the completeness of the release and about potential injury to the tendons or neurovascular structures. The purpose of this study was to assess the efficacy and safety of percutaneous release of the A1 pulley in a cadaveric model u...

متن کامل

The results of percutaneous release of trigger digits by using full handle knife 15 degrees: an anatomical hand surface landmark and clinical study.

OBJECTIVE Know the results of percutaneous release of trigger digits by using full handle knife 15 degrees. MATERIAL AND METHOD The author identified 510 cadaveric digits to find the anatomical landmark of Al pulley that relates to the knuckle and measurements of A1 pulley lengths. The proximal margin of the Al pulleys on the perpendicular line from the knuckle to the palm was in the same lin...

متن کامل

Assessment of the Distal Extent of the A1 Pulley Release: A New Technique

OBJECTIVE Sharp division of the A1 pulley is a time-honored technique for the treatment of flexor tendon entrapment; however, this procedure is not without complications. The anatomy of the A1 pulley system has been carefully investigated. Knowledge of superficial anatomic landmarks can assist with demarcating the distal edge of the A1 pulley and prevent damage to the critical A2 pulley. METH...

متن کامل

Injection versus surgery in the treatment of trigger finger.

One hundred nine trigger fingers in 102 patients were reviewed with respect to management plan and response to treatment. Thirty-four digits eventually underwent surgical release of the A1 pulley, while the other 75 digits were treated with local steroid injection only. All patients were evaluated with respect to clinical resolution of symptoms, dollar cost of treatment, and general satisfactio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010