Evaluating the Transient Impedance of Transmission Line Towers

نویسندگان

  • E. Petrache
  • A. Phillips
چکیده

The low-frequency methods used by most utilities nowadays for measuring the resistance of transmission line ground electrodes are inaccurate or cannot be applied when overhead groundwires are connected to the towers. Moreover, many of them are costly and time consuming. This paper proposes and compares two new methods for evaluating the transient impedance of transmission line towers. Both methods simulate the lightning-like impulse injection into the transmission tower base and measure the resulting potential rise relative to a remote ground.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo method for estimating backflashover rates on high voltage transmission lines

This paper presents a novel Monte-Carlo based model for the analysis of backflashover rate (BFOR) on high voltage transmission lines. The proposed model aims to take into the account following aspects of the BFOR phenomenon: transmission line (TL) route keraunic level(s), statistical depiction of lightningcurrent parameters (including statistical correlation), electrogeometric model of lightnin...

متن کامل

مطالعات ساختاری- اقتصادی طرح ارتقای سیستم انتقال 63 کیلوولت دو مداره سراوان – سوران به سطح 230 کیلوولت

Upgrading the voltage level of a transmission line is named as one solution to increase the transmitted power. This paper introduces the results of a research project in which the upgrade of Saravan-Sooran double circuit transmission system from 63 kV to 230 kV is studied. In this context, the towers remain in their current locations, where the new structure of towers and insulators as well as ...

متن کامل

Using a VIA-Less CRLH Transmission Line to Design Compact Wilkinson Power Dividers and Rat-Race Couplers

A method for design and implementation of a compact via-less Composite Right/Left-Handed Transmission Line (CRLH TL) is presented. By introducing a new circuit model, the CRLH transmission line behavior is studied versus the parameters variations to achieve the desired characteristic impedance and electrical length. Then a compact quarter wavelength CRLH transmission line with 70 Ω characte...

متن کامل

تحلیل و طراحـی دکلهای انتقال نیـرو با استفاده از نظریه قابلیت اعتماد

At the moment, Moshanir loading code which has been provided by Tavanir Company in 1998 is used for loading transmission line towers. Also ASCE52 are applied for designing these structures. In the above Moshanir loading code, loading parameters such as, maximum yearly ice thickness, maximum monthly ice thickness, maximum yearly wind speed and maximum monthly wind speed have been considered as ...

متن کامل

A new expression for the ground transient resistance matrix elements of multiconductor overhead transmission lines

The ground impedance matrix elements of a multiconductor overhead transmission line do not have analytical inverse Fourier transforms in the time domain. Thus, in general, the ground transient resistance matrix elements are to be determined numerically. Using the low-frequency approximation analytical expressions are available for the ground transient resistance. These expressions present howev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007