and surgery type on surgery times during laparoscopic ovariectomy and salpingectomy in captive African lions and cheetahs

نویسندگان

  • Marthinus Jacobus Hartman
  • Eric Monnet
  • Robert Murco Kirberger
  • Johan Petrus Schoeman
چکیده

Background: A prospective randomized study was used to compare surgery times for laparoscopic ovariectomy and salpingectomy in female African lion (Panthera leo) (n = 14) and cheetah (Acinonyx jubatus) (n = 20) and to compare the use of a multiple portal access system (MPAS) and single portal access system (SPAS) between groups. Two different portal techniques were used, namely MPAS (three separate ports) in lions and SPAS (SILS port) in cheetahs, using standard straight laparoscopic instruments. Portal access system and first ovary was not randomized. Five different surgery times were compared for the two different procedures as well as evaluating the use and application of MPAS and SPAS. Carbon dioxide volumes for lions were recorded. Results: In adult lionesses operative time (OPT) (P = 0.016) and total surgical time (TST) (P = 0.032) were significantly shorter for salpingectomy compared to ovariectomy. Similarly in cheetahs OPT (P = 0.001) and TST (P = 0.005) were also shorter for salpingectomy compared to ovariectomy. In contrast, in lion cubs no difference was found in surgery times for ovariectomy and salpingectomy. Total unilateral procedure time was shorter than the respective bilateral time for both procedures (P = 0.019 and P = 0.001) respectively and unilateral salpingectomy was also faster than unilateral ovariectomy (P = 0.035) in cheetahs. Port placement time, suturing time and TST were significantly shorter for SPAS compared to MPAS (P = 0.008). There was, however, no difference in OPT between SPAS and MPAS. Instrument cluttering with SPAS was found to be negligible. There was no difference in mean volume CO2 required to complete ovariectomy in lions but the correlation between bodyweight and total volume of CO2 in lions was significant (rs = 0.867; P = 0.002). Conclusions: Laparoscopic salpingectomy was faster than ovariectomy in both adult lions and cheetahs. Using SPAS, both unilateral procedures were faster than bilateral procedures in cheetahs. Placement and suturing of SPAS in cheetahs was easier and faster compared to three separate ports in lions and lion cubs. The use of standard straight instruments during SPAS did not prolong surgery. Surgery was faster in cubs and CO2 required for laparoscopic sterilization in lions could be determined. Predictable surgery times and CO2 volumes will facilitate the accurate planning and execution of surgery in lions and cheetahs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of portal access system and surgery type on surgery times during laparoscopic ovariectomy and salpingectomy in captive African lions and cheetahs

BACKGROUND A prospective randomized study was used to compare surgery times for laparoscopic ovariectomy and salpingectomy in female African lion (Panthera leo) (n = 14) and cheetah (Acinonyx jubatus) (n = 20) and to compare the use of a multiple portal access system (MPAS) and single portal access system (SPAS) between groups. Two different portal techniques were used, namely MPAS (three separ...

متن کامل

Single-Incision Laparoscopic Sterilization of the Cheetah (Acinonyx jubatus).

OBJECTIVE To describe laparoscopic ovariectomy and salpingectomy in the cheetah (Acinonyx jubatus) using single-incision laparoscopic surgery (SILS). STUDY DESIGN Prospective cohort. ANIMALS Female cheetahs (Acinonyx jubatus) (n = 21). METHODS Cheetahs were randomly divided to receive either ovariectomy (n = 11) or salpingectomy (n = 10). The use and complications of a SILS port was evalu...

متن کامل

Laparoscopic sterilization of the African Lioness (Panthera leo).

OBJECTIVE To describe laparoscopic ovariectomy and salpingectomy in the African lioness (Panthera leo). STUDY DESIGN Descriptive clinical study. ANIMALS Female lions (n = 16). METHODS Lionesses were randomly divided into 2 groups: O = ovariectomy (n = 8) and S = salpingectomy (n = 8) for laparoscopic surgery. Two Veress needle placement techniques were used. RESULTS Laparoscopic ovariec...

متن کامل

Comparison between two portal laparoscopy and open surgery for ovariectomy in dogs

Ovariectomy (OVE) is a routine surgical procedure for neutering in small animal practice. Laparoscopy is a new surgical technique which contains advantages such as less trauma, smaller incision and excellent visualization than traditional open surgery. The present study was conducted to examine the feasibility and safety of laparoscopic procedure through two portal comparing with the convention...

متن کامل

Laparoscopic removal of a large abdominal foreign body granuloma using single incision laparoscopic surgery (SILS) and extraction bag in a cheetah (Acinonyx jubatus)

To cite: Hartman MJ, Kirberger RM, Tordiffe ASW, et al. Vet Rec Case Rep Published online: [please include Day Month Year] doi:10.1136/vetreccr2014-000162 SUMMARY This case presents a thorn-induced abdominal foreign body granuloma that was removed with single incision laparoscopic surgery and an extraction bag. An 11-yearold female cheetah presented for routine laparoscopic ovariectomy. Abdomin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016