Validation of a new method for determination of cup orientation in THA.
نویسندگان
چکیده
Our goal was to validate accuracy, consistency, and reproducibility/reliability of a new method for determining cup orientation in total hip arthroplasty (THA). This method allows matching the 3D-model from CT images or slices with the projected pelvis on an anteroposterior pelvic radiograph using a fully automated registration procedure. Cup orientation (inclination and anteversion) is calculated relative to the anterior pelvic plane, corrected for individual malposition of the pelvis during radiograph acquisition. Measurements on blinded and randomized radiographs of 80 cadaver and 327 patient hips were investigated. The method showed a mean accuracy of 0.7 +/- 1.7 degrees (-3.7 degrees to 4.0 degrees) for inclination and 1.2 +/- 2.4 degrees (-5.3 degrees to 5.6 degrees) for anteversion in the cadaver trials and 1.7 +/- 1.7 degrees (-4.6 degrees to 5.5 degrees) for inclination and 0.9 +/- 2.8 degrees (-5.2 degrees to 5.7 degrees) for anteversion in the clinical data when compared to CT-based measurements. No systematic errors in accuracy were detected with the Bland-Altman analysis. The software consistency and the reproducibility/reliability were very good. This software is an accurate, consistent, reliable, and reproducible method to measure cup orientation in THA using a sophisticated 2D/3D-matching technique. Its robust and accurate matching algorithm can be expanded to statistical models.
منابع مشابه
Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?
PURPOSE The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. MATERIALS AND METHODS We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and com...
متن کاملThe Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications
In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon....
متن کاملA New Approach for Determination of Neck-Pore Size Distribution of Porous Membranes via Bubble Point Data
Reliable estimation of the porous membranes neck-pore size distribution (NPSD) is the key element in the design and operation of all membrane separation processes. In this paper, a new approach is presented for reliable of NPSD of porous membranes using wet flow-state bubble point test data. For this purpose, a robust method based on the linear regularization theory is developed to extract NPSD...
متن کاملDevelopment and Validation of a Rapid Derivative Spectrophotometric Method for Determination of Tropicamide in Eye Drops
Tropicamide is an antimuscarinic agent used as eye drops for refractive examinations. The aim of this study was to develop a simple and suitable analytical method for determination of tropicamide in eye drops in the presence of excipients. A zero-crossing third and fourth derivative spectrophotometric method was described for determination of tropicamide in eye drops. The measurements wer...
متن کاملNon Aqueous Titration for the Determination of Azelaic Acid: Introduction and Method Validation
Alpha-hydroxylic acids are widely used in the treatment and control of skin disorders. Azelaic acid is a naturally occuring Alpha-hydroxy acid that can be formed endogenously from long-chain dicardoxylic acids, metabolism of oleic acid or omega oxidation of mono carboxylic acids. It shows bacteriostatic and bactericidal activities against aerobic and anaerobic micro-organisms present on acne-be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic research : official publication of the Orthopaedic Research Society
دوره 27 12 شماره
صفحات -
تاریخ انتشار 2009