Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification.

نویسندگان

  • Gavin Hamilton
  • Michael S Middleton
  • Mark Bydder
  • Takeshi Yokoo
  • Jeffrey B Schwimmer
  • Yuko Kono
  • Heather M Patton
  • Joel E Lavine
  • Claude B Sirlin
چکیده

PURPOSE To compare PRESS and STEAM MR spectroscopy for assessment of liver fat in human subjects. MATERIALS AND METHODS Single-voxel (20 x 20 x 20 mm) PRESS and STEAM spectra were obtained at 1.5T in 49 human subjects with known or suspected fatty liver disease. PRESS and STEAM sequences were obtained with fixed TR (1500 msec) and different TE (five PRESS spectra between TE 30-70 msec, five STEAM spectra between TE 20-60 msec). Spectra were quantified and T2 and T2-corrected peak area were calculated by different techniques. The values were compared for PRESS and STEAM. RESULTS Water T2 values from PRESS and STEAM were not significantly different (P = 0.33). Fat peak T2s were 25%-50% shorter on PRESS than on STEAM (P < 0.02 for all comparisons) and there was no correlation between T2s of individual peaks. PRESS systematically overestimated the relative fat peak areas (by 7%-263%) compared to STEAM (P < 0.005 for all comparisons). The peak area given by PRESS was more dependent on the T2-correction technique than STEAM. CONCLUSION Measured liver fat depends on the MRS sequence used. Compared to STEAM, PRESS underestimates T2 values of fat, overestimates fat fraction, and provides a less consistent fat fraction estimate, probably due to J coupling effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is MR Spectroscopy Really the Best MR-Based Method for the Evaluation of Fatty Liver in Diabetic Patients in Clinical Practice?

OBJECTIVE To investigate if magnetic resonance spectroscopy (MRS) is the best Magnetic Resonance (MR)-based method when compared to gradient-echo magnetic resonance imaging (MRI) for the detection and quantification of liver steatosis in diabetic patients in the clinical practice using liver biopsy as the reference standard, and to assess the influence of steatohepatitis and fibrosis on liver f...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques

Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...

متن کامل

Extraneous lipid contamination in single-volume proton MR spectroscopy: phantom and human studies.

PURPOSE To determine the degree of extraneous lipid contamination in defined volumes of interest studied with single-volume proton MR spectroscopy. METHODS Single-volume proton MR spectroscopy was performed on a fat/water phantom and in three volunteers using the stimulated-echo acquisition mode (STEAM) and point-resolved spectroscopy (PRESS) localization methods. Three different volumes of i...

متن کامل

Spectroscopic localization by simultaneous acquisition of the double-spin and stimulated echoes.

PURPOSE To design a proton MR spectroscopy ((1) H-MRS) localization sequence that combines the signal-to-noise-ratio (SNR) benefits of point resolved spectroscopy (PRESS) with the high pulse bandwidths, low chemical shift displacements (CSD), low specific absorption rates (SAR), short echo times (TE), and superior radiofrequency transmit field (B1+) immunity of stimulated echo acquisition mode ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2009