The application of single-lumen endotracheal tube anaesthesia with artificial pneumothorax in thoracolaparoscopic oesophagectomy.
نویسندگان
چکیده
Double-lumen endotracheal tube (DLET) anaesthesia is the commonly used method in minimally invasive oesophagectomy (MIE). However, DLET intubation does have its disadvantages. Firstly, the placement of the DLET needs a skilled anaesthetist with familiarity of the technique and subsequent ability to perform a fibre-optic bronchoscopy for confirmation. Secondly, DLET intubation and one-lung ventilation are associated with numerous complications, including hoarseness, tracheobronchial injury and vocal injury. In this report, a retrospective analysis was performed on 42 consecutive patients who underwent MIE using single-lumen endotracheal tube (SLET) anaesthesia with CO2 artificial pneumothorax compared with 81 patients who underwent the same procedure with DLET intubation. Our findings showed that SLET intubation with artificial pneumothorax by CO2 insufflation is a feasible and safe method for MIE procedures.
منابع مشابه
The impact of various artificial pneumothorax on the quality of surgical exposure in thoracic esophageal laparoscopic surgery
Objective: This study is to explore the impact of different pressure of artificial pneumothorax on surgical exposure and patients’ respiratory and circulation in thoracic esophageal laparoscopic surgery. Method: The 60 esophageal cancer patients were randomly divided into 2 groups: the experiment group (single lumen endotracheal intubation with artificial pneumothorax pressure of 9 mmHg) and th...
متن کاملThe Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers.
BACKGROUND A novel double-lumen endotracheal tube, the Papworth BiVent tube, has been designed to allow the rapid passage of a blocker into either main bronchus, without fibreoptic endoscopic guidance. METHODS The feasibility of lung isolation and one-lung ventilation (OLV) in human cadavers is examined, along with displacement of the bronchus blocker during head and neck movement. RESULTS ...
متن کاملTension pneumothorax complicated by double-lumen endotracheal tube intubation.
Tension pneumothorax is not a rare complication of mechanical ventilation, but its occurrence immediately after intubation with a double-lumen endotracheal tube (DLT) is very rare. Subsequent impairment of the respiratory and cardiovascular function can be life threatening if it is not detected early enough and managed properly. Most reported cases of tension pneumothorax during DLT intubation ...
متن کاملUsefulness of the WuScope to facilitate double-lumen endotracheal tube placement in a patient with ankylosing spondylitis.
Functional separation of the lungs may be accomplished by several methods. Patients with a stiff neck and limited mouth opening restrict options to a one-lung ventilation. We report the use of the WuScope video system, a new tool for facilitating double-lumen endotracheal tube placement for one-lung ventilation, in a patient who suffered from ankylosing spondylitis with a stiff, flexed neck and...
متن کاملMassive Emphysema and Pneumothorax Following Shoulder Arthroscopy under General Anaesthesia: A Case Report
The patient was a 61-year-old female with massive rotator cuff tear who had no history of smoking, COPD, asthma, or other pulmonary diseases. Four hours following shoulder arthroscopy, the patient developed progressive dyspnea, which was diagnosed as pneumothorax with subcutaneous emphysema extending to the neck and face. Chest tube was inserted promptly. The patient was discharged with a good ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2014