Accuracy of amniotic fluid lamellar body counting for evaluating fetal lung maturity.

نویسندگان

  • Elahe Zarean
  • Farnaz Memarzadeh
  • Behrooz Fadaei
چکیده

BACKGROUND Respiratory distress syndrome (RDS) is one of the important causes of mortality in neonates. This study was designed to assess the role of the amniotic fluid lamellar body counting in predicting fetal lung maturity. METHOD This study was conducted during 2010, April to 2011, February, at Isfahan University of Medical Sciences, Isfahan, Iran. One hundred and twenty eight amniotic fluid samples were obtained during normal delivery, or before rupturing the membrane in cesarean, and lamellar body was assessed by cellular counter. The respiratory statuses of neonates were determined at delivery and the optimal cut-off point was assessed by receiver operating characteristic (ROC) curve. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were evaluated in optimal cut-off point. RESULTS One hundred and twenty eight amniotic samples and 131 infants were evaluated. The means of maternal and gestational ages were 28.12 +/- 3.84 years and 32.56 +/- 2.72 weeks, respectively. The mean of lamellar body was 31266 +/- 15831 microl in matured lung infants compared to 63081 +/- 16966 microl in immature lung infants (p < 0.001). The optimal cut-off point was evaluated as 47500 microl in predicted pulmonary maturity with sensitivity of 85.1%, specificity of 91.2%, positive predictive value of 92.6% and negative predictive value of 82.5%. CONCLUSION This study indicated that lamellar body counting test has a high positive predictive value with a good sensitivity, specificity and negative predictive value. Future studies for different cellular counters are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting lung maturity in preterm rupture of membranes via lamellar bodies count from a vaginal pool: a cohort study

BACKGROUND Amniocentesis is the accepted mode of attaining amniotic fluid to perform tests for fetal lung maturity. The purpose of this study was to validate a non-invasive fetal lung maturity test by counting lamellar bodies from a vaginal pool among women with preterm premature rupture of membranes. METHODS In a prospective study, amniotic fluid specimens were collected from a vaginal pool ...

متن کامل

Characterizationof AmnioticFluid LametlarBodiesby Resistive-PulseCounting:Relationshipto Measuresof Fetal Lung Maturity

Resistive-pulsecounting studies of amniotic fluid lamellar bodies are presented and demonstrate a strong concordance with the predictions of accepted measures of fetal lung maturity. Uncentrifuged as well as centrifuged specimens could be evaluated, because cells and debris are rejected electronically. The technique is not affected by bilirubin or debris of lysed whole blood, and only mildly by...

متن کامل

Sedimentation of lung-derived phospholipid during low-speed centrifugation of amniotic fluid.

In most methods proposed for the assessment of fetal lung maturity, amniotic fluid is subjected to a preliminary low-speed centrifugation in an attempt to separate whole cells and cell debris from lung-derived surfactant phospholipid (lamellar body phospholipid). However, because lamellar body phospholipid is present in amniotic fluid in a membranous or particulate form, it is also partly sedim...

متن کامل

The ways of amniotic fluid sampling and its influence on lamellar body count.

Even though artificial surfactant is now available, respiratory distress syndrome still remains a serious problem in neonatology. Prenatal analysis of the amniotic fluid can provide data giving insight into the fetal lung maturity, which enables planning of the further outcome of high-risk pregnancies. Surfactant prevents atelectasis by forming a layer rich in phospholipids between the air and ...

متن کامل

Lamellar body phospholipid content of amniotic fluid and L/S ratio compared in assessing fetal lung maturity.

A micro-method has been devised for isolating a lung-derived membranous fraction from human amniotic fluid. The phospholipid content of this fraction, known as lamellar body phospholipid, provides an indication of fetal lung maturity (Ann. Clin. Biochem 16: 191, 1979). This method has now been applied to 479 samples of amniotic fluid from 330 pregnancies. The lecithin/sphingomyelin ratio has al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicinski arhiv

دوره 66 2  شماره 

صفحات  -

تاریخ انتشار 2012