Cannulated Cancellous Screw and Ender’s Nail Fixation in Intertrochanteric Femur Fracture in Elderly Patient With Co-Morbid Condition
نویسندگان
چکیده
Background: Intertrochanteric Femur fracture is common in elderly patient with co-morbidity Aims & Objectives: Clinico-radiological evaluation of results of Ender’s nail and cannulated cancellous screw fixation in case of intertrochanteric fracture of femur in elderly patient with preexisting comorbid condition, and functional recovery in those patients. Results: The patients mainly belong to elder age group with co-morbid condition and all operated within two weeks of fracture. All the fractures were united within an average period of 13 weeks with a range of 10 – 16 weeks. In an average, 20% of the patients had accurate anatomical reduction and the neck -shaft angle was same as on unaffected side, 65% of the patients had 3 to 5 degree of variations in the neck -shaft angle compared to unaffected side, and 15% of patients had more than 10 degree of variation in the neckshaft angle compared to unaffected side. Conclusion: The combined use of Ender’s nail and cannulated cancellous screw may provide good fracture reduction and stability and good functional outcome in elderly patient with intertrochanteric femur fracture.
منابع مشابه
Medial pelvic migration of the lag screw in a short gamma nail after hip fracture fixation: a case report and review of the literature
Hip fractures are a common injury among the elderly. Internal fixation with an intramedullary (IM) system has gained popularity for the treatment of intertrochanteric femur fractures. Multiple complications associated with IM fracture fixation have been described, however, we report a rare complication of medial pelvic migration of the lag screw of a short IM nail in a stable construct ten week...
متن کاملComparions of Compression Hip Screw and Gamma Nail for Intertrochanteric Fractures of the Femur
We conducted a randomised prospective comparison of the Compression Hip Screw(CHS) and gamma nail for internal fixation of 60 intertrochanteric femoral fractures in elderly patients. The gamma nail group showed shorter convalescence and earlier full weight-bearing. There were however no significant differences in the operative time, blood loss, stay in hospital' and patien's mobility at the fin...
متن کاملComparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques
Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...
متن کاملDestabilization of intramedullary fixation with Gamma nail for intertrochanteric fractures with sliding screw cut out Destabilizacja śródszpikowego zespolenia gwoździem Gamma złamań przezkrętarzowych z migracją śruby doszyjkowej do stawu biodrowego
Introduction. Intertrochanteric fractures are located in the proximal upper part of the femur, extracapsulary and extend up to 5 cm under the minor trochanter (3). Intramedullary fixation is used almost exclusively for this kind of fractures in our department for many years. The most common mechanical complication of intramedullary fixation is the cut out of the sliding screw trough the femoral...
متن کاملبررسی کاربرد Short barrel DHS در درمان شکستگی انترتروکانتریک
Cut out or extrusion of the lag screw from the superior aspect of head and neck of the femur is one of the most common and devastating complications of the surgery of the intertrochanteric fractures with DHS. The exact cause of this complications is unknown, but it seems to be related to osteopenia, inappropriate position of lag screw inside head of the femur and inability of DHS to slide insid...
متن کامل