High-Coherence Wavelength Swept Light Source
نویسندگان
چکیده
[Summary] Optical technologies that have so far been restricted to the field of optical communications are now starting to be applied in new fields, especially medicine. Optical Frequency Domain Reflectometry (OFDR) offering fast and accurate target position measurements is one focus of attention. The Wavelength Swept Light Source (WSLS) is said to be one of the key devices of OFDR, whose sweep speed is being increased to support more accurate position tracking of dynamic targets. However, there have been little improvements in coherence length, which has a large impact on OFDR measurement distance and accuracy. Consequently, Anritsu has released high coherence (long coherence length) WSLS. This article evaluates measurable distance ranges used by OFDR with a focus on the coherence length of Anritsu WSLS. We examined the impact of wavelength sweep speed on coherence length. The results show this light source is suitable for OFDR measurements of distances on the order of 10 m to 100 m, demonstrating both high speed and high accuracy measurements over short to long distances. Additionally, since coherence length and wavelength sweep speed change in inverse proportion to each other, it is necessary to select wavelength sweep speed that is optimal for the measurement target.
منابع مشابه
High-Speed Optical Coherence Tomography System Using a 200-kHz Swept Light Source with a KTN Deflector
We demonstrate a high-speed swept-source optical coherence tomography (SS-OCT) system, which is based on a highspeed swept light source and a Mach-Zehnder interferometer with a high-speed photodetector. The light source is an external-cavity laser tuned by a KTN electro-optic deflector, which exhibits a very fast response and large deflection. The scanning wavelength range is almost 80 nm up to...
متن کاملPulsed-source and swept-source spectral-domain optical coherence tomography with reduced motion artifacts.
Significant motion artifacts may arise in conventional spectral-domain optical coherence tomography due to sample or probe motion during the exposure time of a CCD array. We show, for the first time to our knowledge, that the motion artifacts can be greatly reduced by short illumination of individual CCD pixels and that this can be accomplished by use of two distinct classes of light sources: b...
متن کاملUltrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm Citation
The performance and imaging characteristics of ultrahigh speed ophthalmic optical coherence tomography (OCT) are investigated. In vivo imaging results are obtained at 850nm and 1050nm using different configurations of spectral and swept source / Fourier domain OCT. A spectral / Fourier domain instrument using a high speed CMOS linescan camera with SLD light source centered at 850nm achieves spe...
متن کاملWavelength swept amplified spontaneous emission source.
We present a new, alternative approach to realize a wavelength swept light source with no fundamental limit to sweep speed. Amplified spontaneous emission (ASE) light alternately passes a cascade of optical gain elements and tunable optical bandpass filters. We show that for high sweep speeds, the control signal for the different filters has to be applied with a defined, precise phase delay on ...
متن کاملImaging limbal and scleral vasculature using Swept Source Optical Coherence Tomography.
We demonstrate an application of high-speed swept source optical coherence tomography for vessel visualization in the anterior segment of the human eye. The human corneo-scleral junction and sclera was imaged in vivo. Imaging was performed using a swept source OCT system operating at the 1050nm wavelength range and 100kHz A-scan rate. High imaging speed enables the generation of 3D depth-resolv...
متن کامل