Field expansion for homonymous hemianopia by optically induced peripheral exotropia.
نویسنده
چکیده
PURPOSE To describe a novel method for prism correction of hemianopia that provides field-of-view expansion in a convenient and functional format and to evaluate initial clinical application. METHOD To expand the upper quadrant of the field, a high power prism segment (30-40delta) is placed base-out across the upper part of the spectacle lens, on the side of the loss, at about the level of the limbus. A similar prism segment at the lower part of the lens is used to treat the lower field. The peripheral location of the prisms causes peripheral exotropia. As a result a scene segment as high as the vertical span of the prism is shifted laterally by 15 to 20 degrees relative to the view of the other eye. At the edge of the hemianopic field loss, objects that would fall in the scotoma of one eye are seen through the prism in the other eye, providing a simultaneous awareness of details within the otherwise absent field-of-view. An approach for fitting the system to patients with abnormal binocular vision (strabismus and amblyopia, with or without diplopia) is discussed as well. The effect of the prisms was evaluated in a noncomparative case series (12 patients). RESULTS The field expansion is provided at any position of lateral gaze, including gaze away from the side of the scotoma. The effect of this technique on field expansion was demonstrated using standard binocular perimetry. Most patients reported substantial improvement in function and in obstacle avoidance. CONCLUSION A novel method for the optical treatment of hemianopia was developed and tested. It was found to be effective in expanding the field and helping patients' mobility.
منابع مشابه
Torsional anomalous retinal correspondence effectively expands the visual field in hemianopia.
PURPOSE Exotropia in congenital homonymous hemianopia has been reported to provide field expansion that is more useful when accompanied with harmonious anomalous retinal correspondence (HARC). Torsional strabismus with HARC provides a similar functional advantage. In a subject with hemianopia demonstrating a field expansion consistent with torsion, we documented torsional strabismus and torsion...
متن کاملCommunity-based trial of a peripheral prism visual field expansion device for hemianopia.
OBJECTIVE To determine the functional utility for general mobility of peripheral prism glasses, a novel visual field expansion device for hemianopia, in a large-scale, community-based, multicenter study with long-term follow-up. METHODS Forty-three participants with homonymous hemianopia were fitted with temporary press-on Fresnel peripheral prism segments of 40 prism diopters. Follow-up ques...
متن کاملSilent Myocardial Infarction Presented with Homonymous Hemianopia: A Rare Case Study
Silent myocardial infarction is a little-known phenomenon, the mechanisms of which have still remained unclear. Herein, we presented the case of a middle-aged man suffering from silent myocardial infarction who presented with homonymous hemianopia and no other major cardiovascular risk factors, except for stage 1 hypertension.
متن کاملClinical and laboratory evaluation of peripheral prism glasses for hemianopia.
PURPOSE Homonymous hemianopia (the loss of vision on the same side in each eye) impairs the ability to navigate and walk safely. We evaluated peripheral prism glasses as a low vision optical device for hemianopia in an extended wearing trial. METHODS Twenty-three patients with complete hemianopia (13 right) with neither visual neglect nor cognitive deficit enrolled in the 5-visit study. To ex...
متن کاملTreating Hemianopia Using Prisms to Create Peripheral Diplopia
Most optical aids for hemianopia provide only field relocation while field expansion is the desired effect and thus, these aids are rarely successful. This paper describes a novel method for prism correction of hemianopia that provides actual field expansion in a convenient and functional format. To expand the upper quadrant of the field, a high power prism segment (30-40 PD) is placed base-out...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optometry and vision science : official publication of the American Academy of Optometry
دوره 77 9 شماره
صفحات -
تاریخ انتشار 2000