Spot sputum samples are at least as good as early morning samples for identifying Mycobacterium tuberculosis
نویسندگان
چکیده
BACKGROUND The use of early morning sputum samples (EMS) to diagnose tuberculosis (TB) can result in treatment delay given the need for the patient to return to the clinic with the EMS, increasing the chance of patients being lost during their diagnostic workup. However, there is little evidence to support the superiority of EMS over spot sputum samples. In this new analysis of the REMoxTB study, we compare the diagnostic accuracy of EMS with spot samples for identifying Mycobacterium tuberculosis pre- and post-treatment. METHODS Patients who were smear positive at screening were enrolled into the study. Paired sputum samples (one EMS and one spot) were collected at each trial visit pre- and post-treatment. Microscopy and culture on solid LJ and liquid MGIT media were performed on all samples; those missing corresponding paired results were excluded from the analyses. RESULTS Data from 1115 pre- and 2995 post-treatment paired samples from 1931 patients enrolled in the REMoxTB study were analysed. Patients were recruited from South Africa (47%), East Africa (21%), India (20%), Asia (11%), and North America (1%); 70% were male, median age 31 years (IQR 24-41), 139 (7%) co-infected with HIV with a median CD4 cell count of 399 cells/μL (IQR 318-535). Pre-treatment spot samples had a higher yield of positive Ziehl-Neelsen smears (98% vs. 97%, P = 0.02) and LJ cultures (87% vs. 82%, P = 0.006) than EMS, but there was no difference for positivity by MGIT (93% vs. 95%, P = 0.18). Contaminated and false-positive MGIT were found more often with EMS rather than spot samples. Surprisingly, pre-treatment EMS had a higher smear grading and shorter time-to-positivity, by 1 day, than spot samples in MGIT culture (4.5 vs. 5.5 days, P < 0.001). There were no differences in time to positivity in pre-treatment LJ culture, or in post-treatment MGIT or LJ cultures. Comparing EMS and spot samples in those with unfavourable outcomes, there were no differences in smear or culture results, and positive results were not detected earlier in Kaplan-Meier analyses in either EMS or spot samples. CONCLUSIONS Our data do not support the hypothesis that EMS samples are superior to spot sputum samples in a clinical trial of patients with smear positive pulmonary TB. Observed small differences in mycobacterial burden are of uncertain significance and EMS samples do not detect post-treatment positives any sooner than spot samples.
منابع مشابه
An Early Morning Sputum Sample Is Necessary for the Diagnosis of Pulmonary Tuberculosis, Even with More Sensitive Techniques: A Prospective Cohort Study among Adolescent TB-Suspects in Uganda
The World Health Organization (WHO) recommends collection of two sputum samples for tuberculosis (TB) diagnosis, with at least one being an early morning (EM) using smear microscopy. It remains unclear whether this is necessary even when sputum culture is employed. Here, we determined the diagnostic yield from spot and the incremental yield from the EM sputum sample cultures among TB-suspected ...
متن کاملTHE DETECTION OF Mycobacterium tuberculosis BY PCR IN SPUTUM SAMPLES FROM LONG-TERMTREATED LEPROSY PATIENTS: ASSOCIATIONS WITH SKIN TEST RESULTS AND IMMUNOTHERAPY WITH Mycobacterium vaccae
As part of a series of investigations at Baba Baghi Leprosarium in lran, 44 long-treated leprosy patients were selected for our study. Samples of early morning sputum were obtained from each patient, examined by microscopy for acid-fast bacilli (AFB), and cultured for tubercle bacilli. These tests were negative, but the polymerase chain reaction (PCR) for an insertion sequence believed to b...
متن کاملDiagnostic Accuracy of the PURE-LAMP Test for Pulmonary Tuberculosis at the County-Level Laboratory in China
BACKGROUND Early and effective detection of Mycobacterium tuberculosis (MTB), particularly in smear-negative tuberculosis (TB), is a priority for global TB control. Loop-mediated isothermal amplification with a procedure for ultra rapid DNA extraction (PURE-LAMP) can detect TB in sputum samples rapidly and with high sensitivity and specificity. However, the PURE-LAMP test has not been effective...
متن کاملDevelopment of antigen detection assay for diagnosis of tuberculosis using sputum samples.
The rising incidence of tuberculosis worldwide means an increasing burden on diagnostic facilities, so tests simpler than Ziehl-Neelsen staining are needed. Such tests should be objective, reproducible, and have at least as good a detection limit as 10(4) bacteria/ml. A capture enzyme-linked immunosorbent assay (ELISA) was developed for detection of lipoarabinomannan (LAM) in human sputum sampl...
متن کاملA multicenter study of cross-priming amplification for tuberculosis diagnosis at peripheral level in China.
Cross-Priming Amplification (CPA) has been shown to rapidly and effectively detect Mycobacterium tuberculosis (MTB) in sputum samples under isothermal conditions. However, no performance data exist from peripheral-level tuberculosis (TB) clinics in tuberculosis-endemic countries. We conducted a clinical trial at four county-level TB clinics in China to evaluate the effectiveness of the CPA assa...
متن کامل