Accelerated Time Resolved Inflow with 3D Multi-Echo Radial Trajectories
نویسندگان
چکیده
Introduction: Arterial spin labeling (ASL) sequences which utilize tagging schemes to images the flow of blood have emerged as effective techniques for the non-contrast angiography; however, these techniques typically suffer from long acquisition times, sensitivity to tag delay parameters, and uncertain performance in cases of complex flow [1-3]. To mitigate these errors, we have previously demonstrated the preliminary feasibility of a highly accelerated, dynamic inflow imaging utilizing efficient, short TR 3D radial bSSFP sequences [4]. In this work, we investigate various techniques for further improvements in image quality and acceleration and provide demonstration capabilities in an animal model.. Methods: We have implemented an ECG-triggered, inversionrecovery prepared, bSSFP, 3D sequence capable of imaging with multi-echo 3D radial trajectories [5]. Dynamic inflow images are obtains by subtracting an inversion time (TI) resolved acquisition with a non-selective from an acquis ition with an inversion slab just acquiring the image volume as shown in Figure 1. Radial sampling is performed in an interleaved fashion such that images can be reconstructed at low temporal resolution with limited undersampling or at high temporal with increased undersampling or reduced spatial resolution. With institution board approval, time resolved inflow images were acquired on a clinical 1.5T scanner (Signa HDxGE Healthcare; Waukesha, WI) in five Healthy human volunteers and two Canine aneurysm models. Common imaging parameters include: 4-half echo radial trajectory, FOV=22x22x14cm , flip angle = 45o. In healthy, volunteers an optimized sequence with adiabatic VERSE inversion pulse, iterative SENSE reconstruction, ordering scheme that minimizes k-space jumps and pairs k-space angles, and a high time bandwidth RF was compared to our initial implementation with a standard SLR inversion pulse, paired bit-reverse ordering, standard gridding reconstruction, paired bit reverse projection ordering, and low time bandwidth RF pulse. The optimized protocol achieved 0.7mm isotropic resolution in an imaging time of 3:30 while the previous non-optimized protocol achieved 1mm isotropic spatial resolution in 6:00. Canine aneurysm models were imaging using only the optimized protocol. Results: Figure 2 shows representative comparison of the composite images of the sequences. Both sequences show all major vessels; however, the optimized protocol shows significantly better visualization of small arteries, improved background suppression, and signal intensity. Figure 3, shows dynamic time resolved angiography images acquired in the canine aneurysm model. High temporal resolution dynamic images show visualization of rapid intra-arterial filling effects; which are not possible to visualize with contrast enhanced MRA due to bolus dispersion. The composite angiogram proves excellent visualization of both the main aneurysms and a thrombosed side wall aneurysm ( arrow Figure 3).. Conclusion: Time resolved inflow with 3D radial trajectories provides imaging of arterial filling without bolus dispersion or injection of a contrast agent. The utilization of highly accelerated radial trajectories allows the acquisition of high resolution images in clinically feasible scan times with minimized artifacts from flow and off-resonance banding. Acknowledgements: We gratefully acknowledge GE Healthcare for assistance and support. References: [1]. Bi et al. Proc MRA Club 08 #31 [2] Chen et al. ISMRM 02 #1357 [3] Miyazaki et al. Radiology 248(1):20. [4] Johnson et al MRA Club 09 #25 [5]. Lu et al. MRM 53:692-699 Figure 1. Imaging timing diagram (left) and inversion slab locations (right) for intracranial inflow bSSFP with a FAIR tagging scheme. Solid red lines indicate the inversion volumes and solid white lines the imaging volume.
منابع مشابه
Three-dimensionally accelerated radial parallel MRI with a 32-channel coil system
Introduction: Established parallel-imaging techniques include the one-dimensional or two-dimensional acceleration of data acquisition with Cartesian or non-Cartesian trajectories [1–4]. However, state-of-the-art receiver coil arrays with 32 and more coil elements that are distributed approximately uniformly in space should also enable a three-dimensional (3D) parallel-imaging acceleration, i.e....
متن کاملTime-Resolved MRA using Radial Multi-Echo Sequence and Sliding Window Reconstruction
Introduction: There have been many attempts to increase the temporal resolution of time-resolved MRA, including sliding window reconstruction (1-2), TRICKS (3), and HYPR (4). Although these techniques achieve high frame rates, each frame still contains data acquired over a long temporal window, typically longer than 10 seconds. In other words, the frames have long temporal footprints. We introd...
متن کاملMeasuring 3D knee dynamics using center out radial ultra-short echo time trajectories with a low cost experimental setup
Measuring 3D knee dynamics using center out radial ultra-short echo time trajectories with a low cost experimental setup Martin Krämer, Karl-Heinz Herrmann, Heide Boeth, Christoph von Tycowicz, Christian König, Stefan Zachow, Rainald M Ehrig, Hans-Christian Hege, Georg N Duda, and Jürgen R Reichenbach Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University H...
متن کاملFast and tissue-optimized mapping of magnetic susceptibility and T2* with multi-echo and multi-shot spirals
Gradient-echo MRI of resonance-frequency shift and T2* values exhibit unique tissue contrast and offer relevant physiological information. However, acquiring 3D-phase images and T2* maps with the standard spoiled gradient echo (SPGR) sequence is lengthy for routine imaging at high-spatial resolution and whole-brain coverage. In addition, with the standard SPGR sequence, optimal signal-to-noise ...
متن کامل3D time-resolved contrast-enhanced cerebrovascular MR angiography with subsecond frame update times using radial k-space trajectories and highly constrained projection reconstruction.
HYPR TRICKS is an acquisition method that combines radial k-space trajectories, sampling k-space at different rates (TRICKS), and a new strategy for image reconstruction that uses highly constrained backprojection reconstruction (HYPR). This approach provides 3D time-resolved contrast-enhanced MR angiograms of the cerebral vessels with subsecond frame update times and submillimeter in-plane spa...
متن کامل