Separation of isomeric peptides using electrospray ionization/high-resolution ion mobility spectrometry.

نویسندگان

  • C Wu
  • W F Siems
  • J Klasmeier
  • H H Hill
چکیده

In this paper, the first examples of baseline separation of isomeric macromolecules by electrospray ionization/ion mobility spectrometry (ESI/IMS) at atmospheric pressure are presented. The behavior of a number of different isomeric peptides in the IMS was investigated using nitrogen as a drift gas. The IMS was coupled to a quadrupole mass spectrometer, which was used for identification and selective detection of the electrosprayed ions. The mobility data were used to determine their average collision cross sections. The gas-phase ions of isomeric peptides were found to have different collision cross sections. In all cases, doubly charged ions exhibited significantly (8-20%) larger collision cross sections than the respective singly charged species. The analysis of mixtures of the isomeric peptides clearly demonstrated the capability of IMS to separate gas-phase peptide ions due to small differences in their conformational structures, which cannot be determined by mass spectrometry. An actual resolving power of 80 was achieved for two doubly charged reversed sequenced pentapeptides. Baseline separation was provided for ions differing by only 2.5% in their measured collision cross sections; partial separation was shown for isomeric ions exhibiting differences as small as 1.1%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separation of sodiated isobaric disaccharides and trisaccharides using electrospray ionization-atmospheric pressure ion mobility-time of flight mass spectrometry.

A series of isobaric disaccharide-alditols, four derived from O-linked glycoproteins, and select trisaccharides were rapidly resolved using tandem high resolution atmospheric pressure ion-mobility time-of-flight mass spectrometry. Electrospray ionization was used to create the gas-phase sodium adducts of each carbohydrate. Using this technique it was possible to separate up to three isobaric di...

متن کامل

Evaluation of micro-electrospray ionization with ion mobility spectrometry/mass spectrometry

In recent years, the resolving power of ion mobility instruments has been increased significantly, enabling ion mobility spectrometry (IMS) to be utilized as an analytical separation technique for complex mixtures. In theory, decreasing the drift tube temperature results in increased resolution due to decreased ion diffusion. However, the heat requirements for complete ion desolvation with elec...

متن کامل

Rapid resolution of carbohydrate isomers by electrospray ionization ambient pressure ion mobility spectrometry-time-of-flight mass spectrometry (ESI-APIMS-TOFMS).

Carbohydrates are an extremely complex group of isomeric molecules that have been difficult to analyze in the gas phase by mass spectrometry because (1) precursor ions and product ions to successive stages of MS(n) are frequently mixtures of isomers, and (2) detailed information about the anomeric configuration and location of specific stereochemical variants of monosaccharides within larger mo...

متن کامل

Separation of benzodiazepines by electrospray ionization ion mobility spectrometry–mass spectrometry

Benzodiazepines are a commonly abused class of drugs; requiring analytical techniques that can separate and detect the drugs in a rapid time period. In this paper, the two-dimensional separation of five benzodiazepines was shown by electrospray ionization (ESI) ion mobility spectrometry (IMS)–mass spectrometry (MS). In this study, both the two dimensions of separation (m/z and mobility) and the...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 2000