Evaluation of the Colin STBP-680 at rest and during exercise: an automated blood pressure monitor using R-wave gating.

نویسندگان

  • V Bond
  • D R Bassett
  • E T Howley
  • J Lewis
  • A J Walker
  • P D Swan
  • R J Tearney
  • R G Adams
چکیده

The application of automated blood pressure measurement during exercise has been limited by inaccuracies introduced by the effects of accompanying motion and noise. We evaluated a newly developed automated blood pressure monitor for measuring exercise blood pressure (Colin STBP-680; Colin, San Antonio, Texas, USA). The STBP-680 uses acoustic transduction with the assistance of the electrocardiogram R-wave to trigger the sampling period for blood pressure measurement. The automated monitor readings were compared with simultaneous technician mercury sphygmomanometric readings in the same arm. Blood pressure was measured in 18 men at rest and during exercise at 40% VO2 peak, (low intensity), 70% VO2 peak (moderate intensity) and VO2 peak (high intensity) on the cycle ergometer. Mean(s.d.) systolic blood pressure difference between the automated monitor and mercury manometer readings at rest and during exercise at low, moderate and high work intensities were 3(0) mmHg, 3(2) mmHg, 1(1) mmHg, and 0(11) mmHg respectively (analysis of variance; P > 0.05). Resting diastolic blood pressure obtained with the STBP-680 was similar to the mercury manometer readings (78(10) versus 81(7) mmHg (P > 0.05). Exercise diastolic pressure at the low level of work intensity was almost identical between the automated monitor and mercury manometer readings (64(8) versus 65(10) mmHg (not significant)). Diastolic blood pressure readings between the STBP-680 and mercury manometer showed a greater difference at the moderate and high workloads (11 mmHg and 9 mmHg, respectively), but this difference was not significant (P > 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

THE EFFECT OF ARTERIAL O2 SATURATION AND HE ART RATE ON BLOOD PRESSURE DURING HYPOXIA

A periodic increase in blood pressure (BP) occurs during apneic episodes in patients with obstructive sleep apnea (OSA). Several factors including hypoxemia and an increase in heart rate (HR) were reported to be responsible for this increased BP. To examine the contribution of these two factors in increasing BP, 35 healthy male subjects (mean age±SD= 23.64±3.80) were studied in three experi...

متن کامل

Synergic effect of aerobic exercise training (Moderate Intensity) and Soya Intake on Blood Pressure & Rest Heart Rate in Obese Postmenopausal Women

Introduction: In synergic effect of exercise training on reducing cardiovascular disease, soy is a useful source of food in reducing blood pressure and control of heart rate. The purpose of this study was to investigate the synergic effect of short aerobic moderate intensity exercise and soya intake on blood pressure & rest heart rate in obese postmenopausal women. Methods: The present study...

متن کامل

A study of variation in cardiocirculatory parameters with different body positions during isometric exercise in young adult males.

Introduction: To study the effects of exercise, how important it is to choose a posture? We aimed to characterize the possible impact of different body positions on cardiovascular parameters during and after sustained isometric handgrip (IHG) exercise. Materials and Methods: Cross sectional study was carried out in 33 young adult males (mean age: 19.21±1.083 years). We recorded Bloo...

متن کامل

Validation of a generalized transfer function to noninvasively derive central blood pressure during exercise.

Exercise brachial blood pressure (BP) predicts mortality, but because of wave reflection, central (ascending aortic) pressure differs from brachial pressure. Exercise central BP may be clinically important, and a noninvasive means to derive it would be useful. The purpose of this study was to test the validity of a noninvasive technique to derive exercise central BP. Ascending aortic pressure w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of sports medicine

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 1993