Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model.

نویسندگان

  • J H Kim
  • J H Shin
  • D H Shin
  • M-W Moon
  • K Park
  • T-H Kim
  • K M Shin
  • Y H Won
  • D K Han
  • K-R Lee
چکیده

OBJECTIVE Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. METHODS A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). RESULTS The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). CONCLUSION Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice

Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after ...

متن کامل

Sirolimus-eluting stents for the treatment of obstructive superficial femoral artery disease: six-month results.

BACKGROUND Stent implantation for obstructive femoropopliteal artery disease has been associated with poor long-term outcomes. This study evaluated the effectiveness of shape memory alloy recoverable technology (SMART) nitinol self-expanding stents coated with a polymer impregnated with sirolimus (rapamycin) versus uncoated SMART Stents in superficial femoral artery obstructions. METHODS AND ...

متن کامل

Prevention of carotid artery restenosis after sirolimus-coated stent implantation in pigs.

BACKGROUND AND PURPOSE To test the feasibility of self-expanding drug-coated nitinol stents for prevention of restenosis in an animal model. Stent implantation in the carotid artery (CA) has been shown to be feasible for treatment of CA stenosis. Even though the restenosis rate in CA is reported to be lower than in the coronary and peripheral arteries, problems may arise with increasing numbers...

متن کامل

Drug-Coated Balloons for Long Superficial Femoral Artery Disease: Leaving Nothing Behind in the Real-World.

SEE PAGE 950 T he optimal endovascular strategy for treatment of superficial femoral artery (SFA) atherosclerotic disease is an evolving area of research and clinical practice. Initial randomized trials demonstrated a benefit of nitinol self-expanding stent placement in this region when compared to standalone balloon angioplasty (1). However, observational studies subsequently raised concerns r...

متن کامل

Disintegration of a Balloon-Expandable Stent in the Iliac Artery Upon Delivery

Although there are still some controversies on the choice of ideal stent as well as balloon-expandable versus self-expanding stents for aorto-iliac disease; iliac stenting is widely accepted procedure for focal atherosclerotic iliac artery stenosis. Herein, we present an unusual unilateral iliac stenting complication caused by disintegration struts of balloon-expandable stent which was successf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 84 999  شماره 

صفحات  -

تاریخ انتشار 2011