Study of myocardial fiber pathway using magnetic resonance diffusion tensor imaging.
نویسندگان
چکیده
The purpose of this study was to investigate myocardial fiber pathway distribution in order to provide supplemental information on myocardial fiber architecture and cardiac mechanics. Diffusion tensor imaging (DTI) with medium diffusion resolution (15 directions) was performed on normal canine heart samples (N=6) fixed in formalin. With the use of diffusion tensor fiber tracking, left ventricle (LV) myocardial fiber pathways and helix angles were computed pixel by pixel at short-axis slices from base to apex. Distribution of DTI-tracked fiber pathway length and number was analyzed quantitatively as a function of fiber helix angle in step of 9 degrees . The long fiber pathways were found to have small helix angles. They are mostly distributed in the middle myocardium and run circumferentially. Fiber pathways tracked at the middle and upper LV are generally longer than those near the apex. Majority of fiber pathways have small helix angles between -20 degrees and 20 degrees , dominating the fiber architecture in myocardium. Likely, such myocardial fiber pathway measurement by DTI may reflect the spatial connectiveness or connectivity of elastic myofiber bundles along their preferential pathway of electromechanical activation. The dominance of the long and circumferentially running fiber pathways found in the study may explain the circumferential predominance in left ventricular contraction.
منابع مشابه
Three-dimensional diffusion tensor microscopy of fixed mouse hearts.
The relative utility of 3D, microscopic resolution assessments of fixed mouse myocardial structure via diffusion tensor imaging is demonstrated in this study. Isotropic 100-microm resolution fiber orientation mapping within 5.5 degrees accuracy was achieved in 9.1 hr scan time. Preliminary characterization of the diffusion tensor primary eigenvector reveals a smooth and largely linear angular r...
متن کاملMyocardial fiber orientation mapping using reduced encoding diffusion tensor imaging.
A precise knowledge of the myocardial fiber architecture is essential to accurately understand and interpret cardiac electrical and mechanical functions. Diffusion tensor imaging has been used to noninvasively and quantitatively characterize myocardial fiber orientations. However, because the approach necessitates diffusion to be measured in multiple encoding directions and frequently at multip...
متن کاملDiffusion tensor imaging of formalin fixed infarcted porcine hearts: a comparison between 3T and 1.5T
Background Diffusion Tensor Imaging (DTI) quantifies the amount of anisotropic diffusion exhibited by biological tissues. Processing DTI images allow a 3D visualization of the fiber architecture by tracking the fiber trajectories within the tissue. Experimental evidence has shown that the myocardium undergoes remodeling as myocardial infarction progresses over time[1]. The aim of this study is ...
متن کاملHelical structure of the cardiac ventricular anatomy assessed by diffusion tensor magnetic resonance imaging with multiresolution tractography.
INTRODUCTION AND OBJECTIVES Deeper understanding of the myocardial structure linking the morphology and function of the heart would unravel crucial knowledge for medical and surgical clinical procedures and studies. Several conceptual models of myocardial fiber organization have been proposed but the lack of an automatic and objective methodology prevented an agreement. We sought to deepen this...
متن کاملMagnetic resonance myocardial fiber-orientation mapping with direct histological correlation.
Functional properties of the myocardium are mediated by the tissue structure. Consequently, proper physiological studies and modeling necessitate a precise knowledge of the fiber orientation. Magnetic resonance (MR) diffusion tensor imaging techniques have been used as a nondestructive means to characterize tissue fiber structure; however, the descriptions so far have been mostly qualitative. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 25 7 شماره
صفحات -
تاریخ انتشار 2007