2 Parameters of the Bent Solenoid Channel

نویسندگان

  • Kirk T. McDonald
  • Joseph Henry
چکیده

Using the analytic estimates developed for the emittance diagnostic channel for the nal-stage cooling experiment, we conclude that diagnostics for both an initial-stage cooling experiment, and for the targetry experiment could be performed with a bent solenoid of 1.25 T eld strength. The solenoid bore would need to be at least 40 cm for either study. The targetry study is less demanding in accuracy of momentum analysis, and could be accomplished with a smaller bend angle to the solenoid, 0.1 rad, compared to 0.25 rad as appears more appropriate for an initial cooling study. The small bend angle permits a relatively large bend radius, which in turn implies that a relatively weak guiding dipole eld will suuce. That guiding dipole eld could be provided by tilting the coils in the bend region, which would commit the system to a single central momentum. The cost of such magnet systems is estimated to be less $1M per bend, including the straight sections needed for eld uniformity over the TPC's. The cost of the magnets is about half that for a diagnostic channel of nal-stage cooling. Some brief remarks about instrumentation are given.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Instrumentation Channel for the MUCOOL Experiment

The MUCOOL facility is proposed to examine cooling techniques that could be used in a muon collider. The solenoidal beam channel before and after the cooling test section are instrumented to measure the beam emittance. This instrumentation channel includes a bent solenoid to provide dispersion and time projection chambers to measure the beam variables before and after the bend. The momentum of ...

متن کامل

An Emittance Diagnostic Channel for R&D on the Front End of a Muon Collider/Neutrino Factory

Using the analytic estimates developed for the emittance diagnostic channel for the finalstage cooling experiment, we conclude that diagnostics for both an initial-stage cooling experiment, and for the targetry experiment could be performed with a bent solenoid of 1.25 T field strength. The solenoid bore would need to be at least 35 cm for the initial-stage cooling experiment, and at least 50 c...

متن کامل

Muon Dynamics in a Toroidal Sector Magnet

We present a Hamiltonian formulation of muon dynamics in toroidal sector solenoids (bent solenoid).

متن کامل

Geant4 Simulation and Theoretical Studies of a Helical Cooling Channel

We present a conceptual design and detailed GEANT4 simulation of a helical ionization cooling channel proposed by Ya. Derbenev, which is able to cool in 3 dimensions (3D). The lattice of the channel consists of a long solenoid (B=5 T, L=72 m, R=70 cm) and a transverse dipole magnetic field which rotates with a period of 1.8 m and an amplitude of 0.3 T. The cooling is achieved using lithium hydr...

متن کامل

Transmission of Muons in an Alternating Gradient Funneling System

One important issue in a neutrino factory is the target system for pion production. The A.G. funneling system addressed here consists of four horns, with 1 MW target per horn, followed by a recombination A.G. channel and a FODO decay channel. The transmission of this scheme is analyzed in detail. It is compared with that of a simple solenoid for several sets of optics parameters. This study mak...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999