Magnetic resonance in polymer gel dosimetry: techniques and optimization

نویسنده

  • Martin Lepage
چکیده

1. Introduction Magnetic resonance imaging (MRI) can non-invasively and non-destructively probe the magnetization of hydrogen atoms on water molecules in large objects with a high spatial resolution, and in three dimensions. This unique combination of properties is exploited in polymer gel dosimetry since original gel dosimeters, in which viscosity changes were measured and related to the absorbed dose [1], were adapted to obtain a three dimensional dose distribution [2]. The original publication for a 3D dosimeter using MRI dates back to 1990 [3] where a well-known Fricke dosimeter [4] was combined with an aqueous agarose matrix. This followed the observation that irradiation of a ferrous sulfate solution leads to measurable changes in NMR relaxation times [5]. In polymer gel dosimeters, a free radical-induced polymerization reaction leads to the formation of polymer clusters or chains in a gelatin matrix [6-8]. The contrast mechanisms by which MRI can, directly or indirectly, detect the presence of this polymer have already been reviewed [9] and will not be detailed here. Rather, this review will summarize the different MRI techniques that have been applied to date to probe polymer gel dosimeters. The ultimate goal of this, and other, imaging technique is to provide the most precise and accurate dose determination, which implies an optimization in terms of signal-to-noise (SNR) and the absence of imaging artefacts or distortions. All researchers and medical physicists using polymer gel dosimeters do not have access to the same scanners and/or cannot modify the pulse sequences packaged by the manufacturer. This review will thus specify the type of scanner, the field strength, the version, and whether the sequence was available or whether it was modified. Finally, the type of sequence (i.e., multi-slice or 3D) will be reported. Note that some reports were not covered in this review, as they did not provide the uncertainties on the measurements and thus could not be compared adequately. The paper will follow the chronological development of MRI techniques, and their optimization, applied to polymer gel dosimeters. It is not the scope to trace these techniques back to their original authors, since this aspect is covered in a number of excellent reviews and textbooks [e.g., [10,11]].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Uncertainty Analysis in MRI-based Polymer Gel Dosimetry

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

متن کامل

Effect of gold nanoparticles on dose enhancement of 6 Mv X-rayin MAGIC_f polymer gel dosimeter

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...

متن کامل

Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.

A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed to a 6 MV photon beam and the depth dose was compared against a diamond detecto...

متن کامل

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter

Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007