Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents.

نویسندگان

  • S L Goldberg
  • A Colombo
  • S Nakamura
  • Y Almagor
  • L Maiello
  • J M Tobis
چکیده

OBJECTIVES This study was designed to evaluate the changes in intrastent and angiographic dimensions when intravascular ultrasound imaging is used to direct the deployment of balloon-expandable Palmaz-Schatz stents in coronary arteries and saphenous vein grafts. BACKGROUND Intravascular ultrasound provides more information than angiography in the imaging of intravascular structures. Previous studies have shown that obtaining a larger lumen (greater "acute gain") with coronary interventions such as stenting leads to less restenosis and subacute thrombosis. It is not clear whether the information obtained by intravascular ultrasound can be used to obtain a greater acute gain in lumen dimensions. METHODS Forty consecutive patients undergoing Palmaz-Schatz stent implantation had intravascular ultrasound imaging performed after a good angiographic appearance was obtained. If the stent did not appear adequately expanded by intravascular ultrasound, or if the struts were poorly apposed to the arterial wall, further stent dilation with larger balloons or higher pressure inflations were performed. Twenty-nine patients had subsequent intravascular ultrasound imaging. Intrastent diameters and areas were compared from the initial to the final intravascular ultrasound studies. RESULTS Of the 40 patients studied, only 5 (13%) had an adequate result by intravascular ultrasound despite an acceptable angiographic appearance in all patients. Six additional patients did not undergo subsequent intravascular ultrasound imaging. The other 29 patients all demonstrated a significant increase in intrastent minimal diameter (mean 19%), major diameter (11%) and cross-sectional area (34%) (p < 0.001 for all measurements). CONCLUSIONS The use of intravascular ultrasound imaging in the deployment of balloon-expandable Palmaz-Schatz stents leads to a significant increase in intrastent dimensions (greater "acute gain").

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE Trial.A Stent vs. Stent Ultrasound Remodeling Evaluation.

OBJECTIVES We sought to investigate the in vivo mechanical properties of a new self-expanding coronary stent (RADIUS) and, particularly, the subsequent vessel response over time. BACKGROUND Preclinical studies have suggested that self-expanding stents may produce less vessel wall injury at initial deployment, leading to larger follow-up lumens than with balloon-expandable stents. However, the...

متن کامل

Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

متن کامل

Restenosis After Placement of Palmaz - Schatz Stents in Native Coronary Arteries

Background. Several metallic intracoronary stents are currently undergoing preliminary evaluation to ascertain potential benefit as means to reduce the 30-40% incidence of restenosis after balloon angioplasty. Methods and Results. To determine the incidence and correlates of restenosis after placement of Palmaz-Schatz stents in native coronary arteries in the first group of patients selected fo...

متن کامل

Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study.

AIMS Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. METHODS AND RESULTS Angiographic and intravascular ul...

متن کامل

Development in Intracoronary Stents

I n 1964, Dotter et al used the term “stent” to describe wire tubular implants that could be placed in femoral arteries of animals with non-surgical techniques for the first time. The first reports on the use of intravascular stents were made much later, in 1983, by Dotter et al and Gragg et al who placed a wire spring of nitinol in arteries of dogs using a catheter. These reports served as a c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 1994