Diagnostic value of EUS elastography in differentiation of benign and malignant solid pancreatic masses: a meta-analysis.
نویسندگان
چکیده
BACKGROUND/AIMS EUS elastography is a novel technique that can be used for distinguishing benign from malignant lymph nodes and focal pancreatic masses. However, the studies pertaining to EUS elastography for differential diagnosis of solid pancreatic masses have reported widely varied sensitivities and specificities. A meta-analysis of all relevant articles was performed to estimate the overall diagnostic accuracy of EUS elastography for differentiating benign and malignant solid pancreatic masses. METHODS The literatures were identified by searching in PubMed and Embase databases. Two reviewers independently extracted the information from the literatures for constructing 2 × 2 table. A random-effect model or a fixed-effect model was used to estimate the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio. A summary receiver operating characteristic curve (SROC) also was constructed. Meta-regression and subgroup analysis were used to explore the sources of heterogeneity. RESULTS 13 studies including a total of 1042 patients with solid pancreatic masses were selected for meta-analysis. The pooled sensitivity and specificity of EUS elastography for differentiating benign and malignant solid pancreatic masses were 95% (95% confidence interval [CI], 93%-96%), 69% (95% CI, 63%-75%), respectively. The area under SROC (AUC) was 0.8695. Two significant variables were associated with heterogeneity: color pattern and blinding. CONCLUSION As a less invasive modality, EUS elastography is a promising method for differentiating benign and malignant solid pancreatic masses with a high sensitivity, and it can prove to be a valuable supplement to EUS-FNA.
منابع مشابه
EUS elastography for diagnosis of solid pancreatic masses: a meta-analysis.
BACKGROUND The differential diagnosis of solid pancreatic masses has been a significant challenge up until now. EUS elastography is now used as a new technique to distinguish benign from malignant pancreatic masses. However, the sensitivity, specificity, and accuracy are still questionable. OBJECTIVE To evaluate the accuracy of EUS elastography for diagnosis of solid pancreatic masses. DESI...
متن کاملEvaluation of the diagnostic function of shear wave elastography in the differentiation of malignant and benign breast masses and its relationship with histological factors
Background: Shear wave elastography (SWE) estimates the stiffness of a mass based on the velocity of shear wave propagation by sound waves. Due to higher cell density and angiogenesis, malignant masses have higher stiffness than benign ones. Methods: The present study was a prospective study and was performed on patients who were referred to Ahvaz Golestan Hospital with breast mass during Marc...
متن کاملEndoscopic ultrasound in solid pancreatic masses--current state and review of the literature.
Some 25 years ago endoscopic ultrasound (EUS) was introduced in clinical practice for better visualization of pancreas. At the time of introduction EUS was superior to other methods in detection of pancreatic masses allowing tissue diagnosis by later introduced EUS-guided fine needle aspiration (FNA). During the time EUS was improved, electronic probes replaced mechanical probes adding ability ...
متن کاملSecond-generation endoscopic ultrasound elastography in the differential diagnosis of solid pancreatic masses. Pancreatic cancer vs. inflammatory mass in chronic pancreatitis.
Endoscopic ultrasonography (EUS) is considered one of the most accurate methods for the diagnosis and staging of pancreatic tumors. EUS-guided fine-needle aspiration (FNA) allows to increase the diagnostic accuracy of EUS in this setting; however, it is technically demanding (a pathologist is also essential) and is furthermore associated with small, but not insignificant morbidity. EUS pancreat...
متن کاملEndoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study.
AIM To evaluate the ability of endoscopic ultrasound (EUS) elastography to distinguish benign from malignant pancreatic masses and lymph nodes. METHODS A multicenter study was conducted and included 222 patients who underwent EUS examination with assessment of a pancreatic mass (n = 121) or lymph node (n = 101). The classification as benign or malignant, based on the real time elastography pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pancreatology : official journal of the International Association of Pancreatology (IAP) ... [et al.]
دوره 12 5 شماره
صفحات -
تاریخ انتشار 2012