Real-time 3D echocardiographic quantification of left atrial volume: multicenter study for validation with CMR.
نویسندگان
چکیده
OBJECTIVES We studied in a multicenter setting the accuracy and reproducibility of 3-dimensional echocardiography (3DE)-derived measurements of left atrial volume (LAV) using new, dedicated volumetric software, side by side with 2-dimensional echocardiography (2DE), using cardiac magnetic resonance (CMR) imaging as a reference. BACKGROUND Increased LAV is associated with adverse cardiovascular outcomes. Although LAV measurements are routinely performed using 2DE, this methodology is limited because it is view dependent and relies on geometric assumptions regarding left atrial shape. Real-time 3DE is free of these limitations and accordingly is an attractive alternative for the evaluation of LAV. However, few studies have validated 3DE-derived LAV measurements against an accepted independent reference standard, such as CMR imaging. METHODS We studied 92 patients with a wide range of LAV who underwent CMR (1.5-T) and echocardiographic imaging on the same day. Images were analyzed to obtain maximal and minimal LAV: CMR images using standard commercial tools, 2DE images using a biplane area-length technique, and 3DE images using Tomtec LA Function software. Intertechnique comparisons included linear regression and Bland-Altman analyses. Reproducibility of all 3 techniques was assessed by calculating the percentage of absolute differences in blinded repeated measurements. Kappa statistics were used to compare 2DE and 3DE classification of normal/enlarged against the CMR reference. RESULTS 3DE-derived LAV values showed higher correlation with CMR than 2DE measurements (r = 0.93 vs. r = 0.74 for maximal LAV; r = 0.88 vs. r = 0.82 for minimal LAV). Although 2DE underestimated maximal LAV by 31 ± 25 ml and minimal LAV by 16 ± 32 ml, 3DE resulted in a minimal bias of -1 ± 14 ml for maximal LAV and 0 ± 21 ml for minimal LAV. Interobserver and intraobserver variability of 2DE and 3DE measurements of maximal LAV were similar (7% to 12%) and approximately 2 times higher than CMR (4% to 5%). 3DE classified enlarged atria more accurately than 2DE (kappa: 0.88 vs. 0.71). CONCLUSIONS Compared with CMR reference, 3DE-derived LAV measurements are more accurate than 2DE-based analysis, resulting in fewer patients with undetected atrial enlargement.
منابع مشابه
A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملAutomated Quantification of Mitral Regurgitation by Three Dimensional Real Time Full Volume Color Doppler Transthoracic Echocardiography: A Validation with Cardiac Magnetic Resonance Imaging and Comparison with Two Dimensional Quantitative Methods
BACKGROUND Accurate assessment of mitral regurgitation (MR) severity is crucial for clinical decision-making and optimizing patient outcomes. Recent advances in real-time three dimensional (3D) echocardiography provide the option of real-time full volume color Doppler echocardiography (FVCD) measurements. This makes it practical to quantify MR by subtracting aortic stroke volume from the volume...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملLeft Ventricular Ejection Fraction and Volumes: It Depends on the Imaging Method
BACKGROUND AND METHODS In order to provide guidance for using measurements of left ventricular (LV) volume and ejection fraction (LVEF) from different echocardiographic methods a PubMed review was performed on studies that reported reference values in normal populations for two-dimensional (2D ECHO) and three-dimensional (3D ECHO) echocardiography, nuclear imaging, cardiac computed tomography, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JACC. Cardiovascular imaging
دوره 5 8 شماره
صفحات -
تاریخ انتشار 2012