19F-Compressed-Sensing-CISS: Elimination of banding artifacts in 19F bssfp MRI/CSI without sacrificing time

نویسندگان

  • T. C. Basse-Luesebrink
  • A. Fischer
  • T. Kampf
  • V. Sturm
  • G. Ladewig
  • G. Stoll
  • P. M. Jakob
چکیده

The high sensitivity of balanced ssfp (bssfp) sequences makes them important techniques in MRI and CSI. The high sensitivity, however, comes at the cost of banding artifacts in either the image domain (e.g., TrueFISP) or the spectral domain (e.g., bssfp-CSI [1]). Those artifacts can be eliminated using a constructive interference in the steady state (CISS) [2] technique. This, however, results in prolonged measurement times due to the need of additional experiments with different phase cycles. Thus, in particular, the applicability of high resolved bssfp-CSI is limited. Compressed sensing (CS), a reconstruction method for undersampled MR data, was recently introduced [3]. This method allows a reduction in the time needed for experiments, but requires sparsity in the data. The lack of F background signal in living tissue leads to an intrinsically sparse signal distribution in the image domain. This makes F MRI/CSI a suitable target for CS. First applications of CS on F-CSI have been recently demonstrated [4]. The present study focuses on the application of CS in bssfp F-MRI/CSI. The purpose of this application is to gain enough time for the acquisition of additional experiments with different phase cycles. Thus, the goal is to eliminate banding artifacts in the same or less time needed for one phase cycle of a fully sampled bssfp experiment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k

Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...

متن کامل

In-Vivo Detection and Tracking of T Cells in Various Organs in a Melanoma Tumor Model by 19F-Fluorine MRS/MRI

BACKGROUND 19F-MRI and 19F-MRS can identify specific cell types after in-vitro or in-vivo 19F-labeling. Knowledge on the potential to track in-vitro 19F-labeled immune cells in tumor models by 19F-MRI/MRS is scarce. AIM To study 19F-based MR techniques for in-vivo tracking of adoptively transferred immune cells after in-vitro 19F-labeling, i.e. to detect and monitor their migration non-invasi...

متن کامل

Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)

Purpose To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. Materials and Methods CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in 2π dephasing...

متن کامل

Tracking the Fate of Stem Cell Implants with Fluorine-19 MRI

BACKGROUND In this study we used cellular magnetic resonance imaging (MRI) to detect mesenchymal stem cells (MSC) labeled with a Fluorine-19 (19F) agent. 19F-MRI offers unambiguous detection and in vivo quantification of labeled cells. METHODS We investigated two common stem cell transplant mouse models: an immune competent, syngeneic transplant model and an immune compromised, xenograft tran...

متن کامل

Banding Artifact Reduction in 2D CINE Balanced SSFP at 3.0 T Using Phase-Cycling and k-t BLAST

Introduction Balanced steady-state free precession (bSSFP) offers excellent signal-to-noise ratio (SNR) and consistent blood/myocardium contrast which renders 2D CINE bSSFP an ideal clinical choice for LV function assessment [1] at 1.5 T. bSSFP imaging remains challenging at 3.0 T due to its sensitivity to adverse off-resonance effects induced by strong field inhomogeneities at the heart-lung i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009