Estimation of Antioxidative Properties of Phenylacetic Acids Using Ion-exclusion Chromatography

نویسندگان

  • B. K. Głód
  • P. Grieb
چکیده

Cellular oxidative stress has been implicated as a key mechanism of cell differentiation provoked by several compounds (doxorubicins, fibrades, edelfosine). Phenylacetate and its derivatives in submillimolar to millimolar concentrations induce cell differentiation. Ion-exclusion chromatography is widely used for separation and analysis of weak acids. We applied it to the analysis of phenylacetic acids and to the determination of the hydroxyl radical-trapping potential of some of these compounds. Their total antioxidant potential for peroxy radicals was also measured using a photometric method. It was found that phenylacetates are weak antioxidants and in the concentrations which induce cell differentiation effects may substantially reinforce intracellular antioxidative potential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Production of phenylacetic and hydroxyphenylacetic acids by clostridium botulinum type G.

Phenylacetic and hydroxyphenylacetic acids were present as major acids in spent growth medium from Clostridium botulinum type G. These aromatic acids were identified by gas-liquid chromatography and mass spectrometry.

متن کامل

Ion exclusion chromatography of aromatic acids.

The determination of aromatic acids by ion exclusion chromatography is challenging due to peak tailing and the long retention time of hydrophobic solutes. This review discusses the retention mechanisms and the factors affecting retention, eluents and detection methods used in ion exclusion chromatography of aromatic acids such as mono-, di-, tri- and tetra-carboxylic acids, amino acids, sulfona...

متن کامل

Metal-Ion-Coordinating Properties of Various Amino Acids, Investigation of the Essential Function in Biological Systems regarding to their Nano-Structure

The acidity constants of some amino acids (Am) were determined by potentiometric pH titration. The stability constants of the 1:1 complexes formed between M2+: Ca2+, Mg2+, Mn2+, Co2+, Ni2+, Cu2+ or Zn2+ and Am2-, were determined by potentiometric pH titration in aqueous solution (I = 0.1 M, NaNO3, 25°C). The order of the stability constants was reported. It is shown that the stability of the bi...

متن کامل

Metal-Ion-Coordinating Properties of Various Amino Acids, Investigation of the Essential Function in Biological Systems regarding to their Nano-Structure

The acidity constants of some amino acids (Am) were determined by potentiometric pH titration. The stability constants of the 1:1 complexes formed between M2+: Ca2+, Mg2+, Mn2+, Co2+, Ni2+, Cu2+ or Zn2+ and Am2-, were determined by potentiometric pH titration in aqueous solution (I = 0.1 M, NaNO3, 25°C). The order of the stability constants was reported. It is shown that the stability of the bi...

متن کامل

Organic matter from biofilter nitrification by high performance size exclusion chromatography and fluorescence excitation-emission matrix

A combination of high performance size exclusion chromatography with organic carbon detector and ultraviolet detector coupled with peak-fitting technique and fluorescence excitation-emission matrix spectrometry applied fluorescence regional integration method was conducted to determine the characteristics of organic matter during nitrification. The batch scale of bionet nitrification without or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005