Screening of forme fruste keratoconus with the ocular response analyzer.

نویسندگان

  • Cedric Schweitzer
  • Cynthia J Roberts
  • Ashraf M Mahmoud
  • Joseph Colin
  • Sylvie Maurice-Tison
  • Julien Kerautret
چکیده

PURPOSE To evaluate the performance of the Ocular Response Analyzer (ORA) in the screening of forme fruste keratoconus (FFKc). METHODS A retrospective comparative study was conducted involving 180 eyes. ORA preoperative data were analyzed for 125 normal control eyes (64 patients) undergoing laser in situ keratomileusis (LASIK) without corneal ectasia after 24 months of follow-up and 55 case eyes with unilateral keratoconus from a database (BCVA of 1.0, KISA index <60%). All eyes were matched in four groups of central corneal thickness (CCT): group 1, <500 microm; group 2, 500 to 539 microm; group 3, 540 to 579 microm; and group 4 >580 microm. Corneal hysteresis (CH), the corneal resistance factor (CRF), the air pressure curve, and the infrared signal were compared between FFKc and normal eyes in each group. RESULTS The mean CH was 9.1 +/- 1.8 mm Hg for FFKc and 10.3 +/- 1.9 mm Hg for control eyes (P < 0.001), and the mean CRF was 9.2 +/- 1.8 and 11.1 +/- 2 mm Hg (P < 0.001), respectively. Sensitivity in each group was as follows: group 1, CH < 9.5 mm Hg (91%) and CRF < 9.5 mm Hg (81%); group 2, CH < 10.5 mm Hg (91%) and CRF < 10 mm Hg (87%); group 3, CH < 11.5 mm Hg (79%) and CRF < 11 mm Hg (74%); group 4 had two cases of FFKc, and the difference was not significant. Air pressure levels at inward and outward applanation and the maximum air pressure level were significantly lower and shorter in time in FFKc (P < 0.001), whereas the shape of the infrared signal was more variable. CONCLUSIONS The ORA provides additional information in the screening of FFKc, with an accurate analysis of the corneal biomechanical properties according to CCT, air pressure, and infrared curves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Eye Rubbing as a Possible Cause of Clinical Progressive Keratoconus in a Forme Fruste Keratoconic Family

We report a case of a 21-year-old male patient who underwent corneal cross-linking (CXL) due to bilateral progressive keratoconus. Topographical screening of his family members was performed for the detection of possible familial keratoconus and showed abnormal topographical patterns resembling to Forme Fruste Keratoconus (FFK) in all the members of his family. The reported keratoconic patient ...

متن کامل

Corneal Ectasia: prevention and management

Francois Malecaze MD commenced the session with an update on current research into the genetics of keratoconus. Dr Malecaze noted that forme fruste keratoconus is one of the major causes of post-LASIK corneal ectasia and the condition may be due to genetic factors in the majority of cases. Identification of the gene or genes responsible for keratoconus might lead to the development of blood tes...

متن کامل

Comparative Evaluation of Elevation, Keratometric, Pachymetric and Wavefront Parameters in Normal Eyes, Subclinical Keratoconus and Keratoconus with a Dual Scheimpflug Analyzer

Purpose: To compare the corneal parameters in normal corneas, forme fruste keratoconus (FFKC) and keratoconus measured with a dual Scheimpflug analyzer. Materials and methods: A total of 372 eyes of 197 patients were prospectively enrolled in the study and divided into three groups: 148 eyes of 102 patients with keratoconus, 47 contralateral topographically normal eyes of clinically evident ker...

متن کامل

Objective and subjective diagnostic parameters in the fellow eye of unilateral keratoconus

BACKGROUND Keratoconus (KC) is usually a bilateral corneal ectatic disease. For significant asymmetric presentation (so called unilateral KC), the fellow eye has the mildest and earliest form of the disease, which is typically called forme fruste keratoconus. The aim of this study was to evaluate the sensitivity and specificity of parameters derived from a Scheimpflug imaging system (Pentacam) ...

متن کامل

Evaluation of total and corneal wavefront high order aberrations for the detection of forme fruste keratoconus.

PURPOSE To investigate the application of anterior corneal and ocular aberrations in detecting mildly ectatic corneas. METHODS This study retrospectively reviewed the data of 220 eyes separated into three groups by the NIDEK Corneal Navigator System automated corneal classification software: normal (N) (n = 123); forme fruste keratoconus (N topography with contralateral KC) (n = 34); and KC (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 51 5  شماره 

صفحات  -

تاریخ انتشار 2010