[Comparison of intracoronary ultrasound expansion parameters in coronary stents implanted with or without balloon predilatation. A randomized intravascular ultrasound study].

نویسندگان

  • Ramón López-Palop
  • Eduardo Pinar
  • Iñigo Lozano
  • Pilar Carrillo
  • Rocío Cortés
  • Daniel Saura
  • Francisco Picó
  • Mariano Valdés
چکیده

INTRODUCTION AND OBJECTIVES Coronary stenting without balloon predilatation is a safe technique associated with similar clinical results and lower costs, use of contrast and exposure to radiation in comparison to stenting with predilatation. After direct stenting, expansion may be reduced if the stenotic lesion was not predilatated. This study compared a). stent expansion with and without balloon predilatation (direct stenting), observed by intracoronary ultrasound, and b). angiographic results after 6 months and 1 year with the two implantation techniques. PATIENTS AND METHOD 100 consecutive lesions eligible for direct stenting were randomized to stent implantation with or without balloon predilatation. Only <or=25 mm Multilink Duet/Tri-Star/Tetra or NIR Sox/Elite stents were used. When the angiographic result was considered optimal, an independent operator who had not been involved in the procedure performed an intracoronary ultrasound study. The ultrasound examination was not used in decision making unless there was a potential risk for the patient. Ultrasound parameters of expansion were compared in the two implantation techniques with systematic 6- to 9-month angiographic examinations and 1-year clinical follow-up. RESULTS There were no clinical or baseline angiographic differences between the two groups. No significant differences were observed in the ultrasound expansion parameters or the rate of clinical events after 12 months of follow-up. Binary angiographic restenosis (23% vs 20%) and late loss index (0.92 [0.81] vs 0.88 [0.60]) did not differ significantly between the predilatation and direct stenting groups. CONCLUSIONS Direct stenting was not associated with different ultrasound expansion parameters in comparison to the conventional technique. Angiographic restenosis and the rate of long-term clinical events were similar with both techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treating the diabetic patient with coronary disease.

[2] Fishman DL, Leon MB, Bairn DA et al. A randomised comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 1994; 331: 496-501. [3] Colombo A, Hall P, Nakamura S el al. Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation 1995; 91: 1676-88. [4] Monce MC, Zemour G, Benven...

متن کامل

[Randomized intravascular ultrasound comparison between endoprostheses with and without amorphous silicon-carbide].

The superiority of coronary stent implantation over percutaneous transluminal balloon angioplasty in virtually all lesion subsets has led to the wide use of stents for the percutaneous treatment of coronary lesions 1,2. However, in-stent restenosis remains as a major limitation 3,4. Recent data suggest that neointimal proliferation, the cornerstone of in-stent restenosis 5,6, is related to the ...

متن کامل

INTERVENTIONAL CARDIOLOGY AND SURGERY Evaluation of intracoronary stenting by intravascular optical coherence tomography

Background: Conventional contrast cineangiography and intravascular ultrasound (IVUS) provide a limited definition of vessel microstructure and are unable to evaluate dissection, tissue prolapse, and stent apposition on a size scale less than 100 μm. Objective: To evaluate the use of intravascular optical coherence tomography (OCT) to assess the coronary arteries in patients undergoing coronary...

متن کامل

Randomised comparison of coronary stenting with and without balloon predilatation in selected patients.

BACKGROUND The SWIBAP (stent without balloon predilatation) prospective randomised trial was designed to compare direct coronary stenting with stenting preceded by lesion predilatation with an angioplasty balloon. OBJECTIVE To determine the feasibility and safety of direct stenting in non-complex coronary lesions in a prospective study. PATIENTS AND DESIGN All patients < 76 years of age sch...

متن کامل

INTERVENTIONAL CARDIOLOGY AND SURGERY Mechanism of lumen enlargement with direct stenting versus predilatation stenting: influence of remodelling and plaque characteristics assessed by volumetric intracoronary ultrasound

Objective: To compare the effects of arterial remodelling and plaque characteristics on the mechanisms of direct stenting and predilatation stenting. Direct stenting has become routine in some laboratories and differs technically from predilatation stenting. Methods: Preand post-interventional volumetric intravascular ultrasound (IVUS) was undertaken in 30 patients with direct stenting and in 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 57 5  شماره 

صفحات  -