Effect of voxel position on single-voxel MR spectroscopy findings.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Single-voxel MR spectroscopy is a widely used tool for evaluating brain tumors. Although extensive data are available on the MR spectral appearance of tumors, less is known about the effect of voxel position on the accuracy of single-voxel MR spectroscopy findings. The purpose of this study was to test the hypothesis that the accuracy of single-voxel MR spectroscopy in the categorization of lesions as either tumor or not tumor is dependent on voxel position. METHODS Fifty single-voxel MR spectra acquired with a fully automated stimulated-echo spectroscopy sequence were reviewed retrospectively in 43 patients with new or previously treated intra-axial brain tumors. Spectra were analyzed for the presence of choline, creatine, N-acetylaspartate (NAA), and lipid/lactate. Choline/creatine and NAA/creatine peak area ratios were assessed qualitatively. Lesions were grouped into one of three categories on the basis of spectral pattern: tumor, not tumor, or indeterminate. Results of MR spectroscopy were compared with the final histopathologic diagnosis. RESULTS Histologic confirmation was obtained in 19 patients; MR spectra were interpretable in 17 of those. MR spectra correctly categorized nine of 17 lesions (six tumor, three nontumor). All eight misdiagnosed lesions were tumors. When the MR spectroscopy voxel included the enhancing edge of the lesion, the spectra correctly categorized seven of eight lesions (four of five tumors and all three cases of radiation necrosis). When the MR spectroscopy voxel was positioned centrally within the lesion, the spectra correctly reflected histologic outcome in two of nine lesions (all tumors). CONCLUSION The reliability of single-voxel MR spectroscopy findings is dependent on voxel position. Spectra obtained from voxels at the enhancing edge of a tumor more accurately reflect lesion histopathology than do spectra obtained from the lesion center, even if the centrally placed voxels contain solidly enhancing tissue.
منابع مشابه
Prospective motion correction for single-voxel 1H MR spectroscopy.
Head motion during (1)H MR spectroscopy acquisitions may compromise the quality and reliability of in vivo metabolite measurements. Therefore, a three-plane image-based motion-tracking module was integrated into a single-voxel (1)H MR spectroscopy (point-resolved spectroscopy) sequence. A series of three orthogonal spiral navigator images was acquired immediately prior to the MR spectroscopy wa...
متن کاملMalignant Tumors and Chronic Infections in the Masticator Space: Preliminary Assessment with In Vivo Single-Voxel H-MR Spectroscopy
MATERIALS AND METHODS: Twenty-four masticator space lesions, 7 chronic infections, and 17 malignant tumors were assessed with H-MR spectroscopy before treatment procedures. The MR spectroscopic findings were compared with surgical and histopathologic results. Localization technique for H-MR spectroscopy was made by a point-resolved spectroscopy sequence at an echo time of 144 ms. Choline (Cho) ...
متن کاملDevelopment of a cone-shape phantom for multi-voxel MR spectroscopy.
The purpose of this study was to develop a cone-shape phantom for multi-voxel magnetic resonance spectroscopy (MRS) and to evaluate MR spectra using the cone-shape phantom we developed in this study. A cone-shape MRS phantom was developed with a combination of cone-shape vials. The cylindrical main body was made of acrylic resin and the cone-shape vials were fabricated from poly-ethylene cones....
متن کاملMalignant tumors and chronic infections in the masticator space: preliminary assessment with in vivo single-voxel 1H-MR spectroscopy.
BACKGROUND AND PURPOSE Differential diagnosis between malignant tumors and chronic infections in the masticator space remains challenging. The purpose of the study was to categorize various changes of both lesions by using single-voxel 1H-MR spectroscopy. MATERIALS AND METHODS Twenty-four masticator space lesions, 7 chronic infections, and 17 malignant tumors were assessed with 1H-MR spectros...
متن کاملMR imaging, MR angiography, and MR spectroscopy of the brain in eclampsia.
PURPOSE To compare the MR imaging and MR angiographic changes with in vivo proton MR spectroscopic findings and to determine the spectral differences between edema and ischemia in patients with eclampsia. METHODS Spin-echo MR imaging, MR angiography, and single-voxel proton MR spectroscopy were performed in 10 patients with eclampsia. MR studies were obtained within 3 to 5 days of diagnosis a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 21 2 شماره
صفحات -
تاریخ انتشار 2000