Visualizing mass transport in desorption electrospray ionization using time-of-flight secondary ion mass spectrometry.

نویسندگان

  • Shin Muramoto
  • Thomas P Forbes
  • Matthew E Staymates
  • Greg Gillen
چکیده

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to determine the effect of ambient probe incidence angle on the amount and direction of analyte molecules transported from the sample surface for desorption electrospray ionization (DESI). Incidence angle was critical to both the lateral dispersion and vertical take-off angles of analyte molecules desorbed from the surface; as the incidence angle was increased from 30° to 45° to 60° (relative to the sample surface), the lateral dispersion angle decreased from 79° to 71° to 62°, respectively, while the vertical take-off angle decreased dramatically from 12° to 6° to 4°, respectively. As for the amount of material transported, the ToF-SIMS normalized secondary ion intensity of the molecular ion (peak counts per total spectrum counts) showed a significant decrease in the signal when the incidence angle was made steeper, decreasing from 8.1 × 10(-3) to 4.2 × 10(-3) to 7.5 × 10(-4), respectively. The ambient mass spectrometer interfaced with DESI also showed a similar analyte response, where the intensity of the molecular ion decreased from 1.6 × 10(7) counts to 3.3 × 10(6) counts to 5.4 × 10(5) counts, respectively. Overall, a steeper incidence angle was characterized by smaller amount of material desorption and tighter dispersion in both lateral and vertical directions. The study showed how ToF-SIMS can be used as a unique tool for characterizing the transport of desorbed analyte molecules in ambient ionization mass spectrometry, potentially offering new interface designs for optimal analyte collection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated correlation and classification of secondary ion mass spectrometry images using a k-means cluster method.

We present a novel method for correlating and classifying ion-specific time-of-flight secondary ion mass spectrometry (ToF-SIMS) images within a multispectral dataset by grouping images with similar pixel intensity distributions. Binary centroid images are created by employing a k-means-based custom algorithm. Centroid images are compared to grayscale SIMS images using a newly developed correla...

متن کامل

Secondary ionization of chemical warfare agent simulants: atmospheric pressure ion mobility time-of-flight mass spectrometry.

For the first time, the use of a traditional ionization source for ion mobility spectrometry (radioactive nickel ((63)Ni) beta emission ionization) and three alternative ionization sources (electrospray ionization (ESI), secondary electrospray ionization (SESI), and electrical discharge (corona) ionization (CI)) were employed with an atmospheric pressure ion mobility orthogonal reflector time-o...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 139 11  شماره 

صفحات  -

تاریخ انتشار 2014