Influence of implant diameter on surrounding bone.

نویسندگان

  • Jeff Brink
  • Stephen J Meraw
  • David P Sarment
چکیده

OBJECTIVES Implant osseointegration is dependent upon various factors, such as bone quality and type of implant surface. It is also subject to adaptation in response to changes in bone metabolism or transmission of masticatory forces. Understanding of long-term physiologic adjustment is critical to prevention of potential loss of osseointegration, especially because excessive occlusal forces lead to failure. To address this issue, wide-diameter implants were introduced in part with the hope that greater total implant surface would offer mechanical resistance. Yet, there is little evidence that variation in diameter translates into a different bone response in the implant vicinity. Therefore, this study aimed at comparing the impact of implant diameter on surrounding bone. MATERIAL AND METHODS Twenty standard (3.75 mm) and 20 wide (5 mm) implants were placed using an animal model. Histomorphometry was performed to establish initial bone density (IBD), bone to implant contact (BIC) and adjacent bone density (ABD). RESULTS BIC was 71% and 73%, whereas ABD was 65% and 52%, for standard and wide implants, respectively. These differences were not statistically different (P>0.05). Correlation with IBD was then investigated. BIC was not correlated with IBD. ABD was not correlated to IBD for standard implants (r2=0.126), but it was correlated with wide implants (r2=0.82). In addition, a 1 : 1 ratio between IBD and ABD was found for wide implants. It can be concluded, within the limits of this study, that ABD may be influenced by implant diameter, perhaps due to differences in force dissipation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.

This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...

متن کامل

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

نقش پوشش های بیوسرامیکی در موفقیت ایمپلنت ها

Characterization of bioceramics coating and evaluation of the influence of kind of coating on the implantation has been developed in recent years.Different bioceramics coating like calcium phosphate, hydroxyapatite, fluorapatite and bioglass were coated on dental and orthopedic implants. In-vitro and in-vivo experiments were done for evolution of implant success and reliability and study of fac...

متن کامل

The Effect of Bone Type on Peri-implant Bone Stress in Regular and Narrow Diameter Implants on Oblique Loading

Purpose: A three-dimensional (3D) finite element analysis (FEA) was performed to evaluate the influence of bone quality, on the stress/strain in bone surrounding the implant. Materials and methods: Three-dimensional finite element models created to replicate completely osseointegrated endosseous titanium implants, were used for the purpose of stress analysis. Two study groups consisting of a re...

متن کامل

Influence of Implant Design (Cylindrical and Conical) in the Load Transfer Surrounding Long (13mm) and Short (7mm) Length Implants: A Photoelastic Analysis

PURPOSE This study compared the influence of implant design (cylindrical and conical) in the load transfer on bone surrounding 13mm and 7mm length implants under simulated occlusal loading, using photoelastic analysis. METHOD Dental implants of 4mm diameter were divided into four groups, which varied in length and design: Group 1- standard (13 mm) cylindrical implant; Group 2 - standard conic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2007