Closed-Loop Insulin Delivery Using a Subcutaneous Glucose Sensor and Intraperitoneal Insulin Delivery

نویسندگان

  • Eric Renard
  • Jerome Place
  • Martin Cantwell
  • Hugues Chevassus
  • Cesar C. Palerm
چکیده

OBJECTIVE Attempts to build an artificial pancreas by using subcutaneous insulin delivery from a portable pump guided by an subcutaneous glucose sensor have encountered delays and variability of insulin absorption. We tested closed-loop intraperitoneal insulin infusion from an implanted pump driven by an subcutaneous glucose sensor via a proportional-integral-derivative (PID) algorithm. RESEARCH DESIGN AND METHODS Two-day closed-loop therapy (except for a 15-min pre-meal manual bolus) was compared with a 1-day control phase with intraperitoneal open-loop insulin delivery, according to randomized order, in a hospital setting in eight type 1 diabetic patients treated by implanted pumps. The percentage of time spent with blood glucose in the 4.4-6.6 mmol/l range was the primary end point. RESULTS During the closed-loop phases, the mean +/- SEM percentage of time spent with blood glucose in the 4.4-6.6 mmol/l range was significantly higher (39.1 +/- 4.5 vs. 27.7 +/- 6.2%, P = 0.05), and overall dispersion of blood glucose values was reduced among patients. Better closed-loop glucose control came from the time periods excluding the two early postprandial hours with a higher percentage of time in the 4.4-6.6 mmol/l range (46.3 +/- 5.3 vs. 28.6 +/- 7.4, P = 0.025) and lower mean blood glucose levels (6.9 +/- 0.3 vs. 7.9 +/- 0.6 mmol/l, P = 0.036). Time spent with blood glucose <3.3 mmol/l was low and similar for both investigational phases. CONCLUSIONS Our results demonstrate the feasibility of intraperitoneal insulin delivery for an artificial beta-cell and support the need for further study. Moreover, according to a semiautomated mode, the features of the pre-meal bolus in terms of timing and amount warrant further research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closed-loop insulin delivery for treatment of type 1 diabetes

Type 1 diabetes is one of the most common endocrine problems in childhood and adolescence, and remains a serious chronic disorder with increased morbidity and mortality, and reduced quality of life. Technological innovations positively affect the management of type 1 diabetes. Closed-loop insulin delivery (artificial pancreas) is a recent medical innovation, aiming to reduce the risk of hypogly...

متن کامل

Feasibility of closed-loop insulin delivery in type 2 diabetes: a randomized controlled study.

OBJECTIVE Closed-loop insulin delivery offers a promising treatment option, but to date, it has only been evaluated in type 1 diabetes. Our aim was to evaluate the feasibility of fully closed-loop subcutaneous insulin delivery in insulin-naïve patients with type 2 diabetes. RESEARCH DESIGN AND METHODS Twelve subjects (seven males, age 57.2 years, BMI 30.5 kg/m2) with noninsulin-treated type 2...

متن کامل

Automated insulin delivery for t ype 1 diabetes Garry

Purpose of review Automated insulin delivery using the subcutaneous site for both glucose sensing and insulin delivery, while not commercially available, is starting to be implemented in the research environment. Here, we review issues with glucose sensing and insulin delivery algorithms that need to be resolved in order to achieve a closed-loop system. Recent findings Glucose sensing technolog...

متن کامل

Clinical experience with an implanted closed-loop insulin delivery system.

AIM To report the first clinical experience with a prototype of implanted artificial beta-cell. METHODS The Long-Term Sensor System project assessed the feasibility of glucose control by the combined implantation of a pump for peritoneal insulin delivery and a central intravenous glucose sensor, connected physically by a subcutaneous lead and functionally by PID algorithms. It was performed i...

متن کامل

Evaluation of the effect of gain on the meal response of an automated closed-loop insulin delivery system.

A continuous closed-loop insulin delivery system using subcutaneous insulin delivery was evaluated in eight diabetic canines. Continuous glucose profiles were obtained by extrapolation of blood glucose measurements. Insulin delivery rate was calculated, using a model of beta-cell insulin secretion, and delivered with a Medtronic MiniMed subcutaneous infusion pump. The model acts like a classic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2010