Degradation mechanisms and long-term performance of PUR insulation in district heating pipes

نویسنده

  • ALBERTO VEGA
چکیده

District heating networks are used worldwide, especially in Scandinavian countries and also in many other countries, e.g. Germany, Russia, United States, South Korea and China. From an environmental point of view, district heating networks are a good alternative to more traditional building heating systems. In 1970th, the third generation of district heating systems was established on the market, where pressurised hot water was used as a heat carrier. The heat is transported with help of pre-insulated pipes, which should have good mechanical and thermal performance in order to withstand both external and internal loads, and minimize the energy loss. These performances are normally evaluated in accordance with the European Standard EN 253. To estimate the lifetime of pipes, an accelerated thermal ageing is normally performed at higher temperatures than at normal operation. The aim of the studies included in this thesis was to determine the parameters affecting the lifetime of district heating pipes during accelerated ageing tests. In the first part, the focus was on determining the most relevant degradation mechanisms in the insulation foam of district heating pipes. Physical and chemical properties were studied with different methods to establish the most significant degradation processes. After that, district heating pipes were subjected to accelerated ageing at three different temperatures. The results of ageing were obtained after various periods and interpreted using the key findings obtained. It was confirmed that oxygen plays a main role in the activation of the degradation processes, being faster at higher temperatures. The most interesting results were found in the mechanical strength measurements, where the pipe aged at 130 ◦C behaved quite different in comparison with the pipes at 150 and 170 ◦C. These measurements are often used to evaluate the performance of the pipe and in the prediction of lifetime. The degradation pattern of pipes was further confirmed by the results collected from thermal conductivity measurements and analyses of the chemical structure. Our investigation points out that accelerated ageing of pipes at too high temperatures may cause other degradation mechanisms rather than acceleration of the natural processes. This may lead to erroneous estimation of pipe lifetime, leading to incorrect assessment of the district heating networks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Global opportunities in Pipe in Pipe technology

An extensive product range is mandatory to be a key player in the pipe insulation market. The polyurethane preinsulated pipe producers are responding to global opportunities by diversifying their activities into industrial, marine, oil and gas applications. Moreover, the requirements for traditional district heating preinsulated pipes including initial thermal conductivity and its ageing perfor...

متن کامل

Classification and Temporal Analysis of District Heating Leakages in Thermal Images

District heating pipes are known to degenerate with time and in some cities the pipes have been used for several decades. Due to bad insulation or cracks, energy or media leakages might appear. This paper presents a complete system for large-scale monitoring of district heating networks, including methods for detection, classification and temporal characterization of (potential) leakages. The s...

متن کامل

The Impact of Insulation and HVAC Degradation on Overall Building Energy Performance: A Case Study

Through monitoring of buildings, it can be proven that the performance of envelope elements and energy supply systems deteriorates with time. The results of this degradation are higher energy consumption and life cycle costs than projected in the building design phase. This paper considers the impacts of this deterioration on the whole building energy performance with the goal of improving the ...

متن کامل

A review of the main mechanisms of catalyst layer degradation in polymer electrolyte membrane fuel cell (PEMFC) and different performance recovery methods

This paper reviewed over 100 articles on the subject of the mechanism of catalyst layer (CL) degradation and the effect of various contaminations in the polymer electrolyte membrane fuel cell (PEMFC). Also the recovery of PEMFC via different types of methods, the causes and fundamental mechanisms of cell degradation and their influence on long- term performance of PEM fuel cell were discussed i...

متن کامل

بهبود عملکرد سیستم گرمایش از کف با استفاده از پل‌های فلزی

This research is a numerical investigation of the thermal performance of the floor heating system integrated with metallic bridges. For this goal, aluminum and galvanized metallic bridges with 0.5 mm thickness were embedded within the free space of the pipes. Two different bridge lengths of P/S=1/3, 2/3, and 1 were studied in this paper in which P and S are the bridge length and free space betw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018