Comparing Gamma Knife and CyberKnife in patients with brain metastases
نویسندگان
چکیده
The authors compared the relative dosimetric merits of Gamma Knife (GK) and CyberKnife (CK) in 15 patients with 26 brain metastases. All patients were initially treated with the Leksell GK 4C. The same patients were used to generate comparative CK treatment plans. The tissue volume receiving more than 12 Gy (V12), the difference between V12 and tumor volume (V12net), homogeneity index (HI), and gradient indices (GI25, GI50) were calculated. Peripheral dose falloff and three conformity indices were compared. The median tumor volume was 2.50 cm3 (range, 0.044-19.9). A median dose of 18 Gy (range, 15-22) was prescribed. In GK and CK plans, doses were prescribed to the 40-50% and 77-92% isodose lines, respectively. Comparing GK to CK, the respective parametric values (median ± standard deviation) were: minimum dose (18.2 ± 3.4 vs. 17.6 ± 2.4 Gy, p = 0.395); mean dose (29.6 ± 5.1 vs. 20.6 ± 2.8 Gy, p < 0.00001); maximum dose (40.3 ± 6.5 vs. 22.7 ± 3.3 Gy, p < 0.00001); and HI (2.22 ± 0.19 vs. 1.18 ± 0.06, p < 0.00001). The median dosimetric indices (GK vs. CK, with range) were: RTOG_CI, 1.76 (1.12-4.14) vs. 1.53 (1.16-2.12), p = 0.0220; CI, 1.76 (1.15-4.14) vs. 1.55 (1.18-2.21), p = 0.050; nCI, 1.76 (1.59-4.14) vs. 1.57 (1.20-2.30), p = 0.082; GI50, 2.91 (2.48-3.67) vs. 4.90 (3.42-11.68), p < 0.00001; GI25, 6.58 (4.18-10.20) vs. 14.85 (8.80-48.37), p < 0.00001. Average volume ratio (AVR) differences favored GK at multiple normalized isodose levels (p < 0.00001). We concluded that in patients with brain metastases, CK and GK resulted in dosimetrically comparable plans that were nearly equivalent in several metrics, including target coverage and minimum dose within the target. Compared to GK, CK produced more homogenous plans with significantly lower mean and maximum doses, and achieved more conformal plans by RTOG_CI criteria. By GI and AVR analyses, GK plans had sharper peripheral dose falloff in most cases.
منابع مشابه
بررسی بقا بر اساس سیستم نمرهبندی GPA در مبتلایان به متاستازهای مغزی درمان شده با رادیوسرجری گامانایف
Abstract Background: This study was done to define the role of Graded Prognostic Assessment (GPA) score for predicting overall survival in patients diagnosed with brain metastases undergoing Gamma-knife radiosurgery. Materials and methods: Patients diagnosed with brain metastases who were candidates for Gamma-knife radiosurgery entered this cross sectional study between 2003 and 2011. Clin...
متن کاملAssessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کاملThe Value of the History and Physical for Patients with Newly Diagnosed Brain Metastases Considering Radiosurgery
BACKGROUND For patients with brain metastases, systemic disease burden has historically been accepted as a major determinant of overall survival (OS). However, less research has focused on specific history and physical findings made by clinicians and how such findings pertain to patient outcomes at a given time point. The aim of this study is to determine how the initial clinical assessment of ...
متن کاملExceptional Eight-year Response to Stereotactic Radiosurgery Monotherapy for Multiple Brain Metastases
Breast cancer represents the second leading cause of brain metastases in women. Once diagnosed, brain metastases have been associated with a rapidly progressive and universally poor prognosis. Breast cancer patients, particularly those with advantageous disease characteristics, may achieve extended survival. This extended life expectancy highlights the importance of effective intracranial treat...
متن کاملGamma Knife Simulation Using the MCNP4C Code and the Zubal Phantom and Comparison with Experimental Data
Introduction: Gamma Knife is an instrument specially designed for treating brain disorders. In Gamma Knife, there are 201 narrow beams of cobalt-60 sources that intersect at an isocenter point to treat brain tumors. The tumor is placed at the isocenter and is treated by the emitted gamma rays. Therefore, there is a high dose at this point and a low dose is delivered to the normal tissue surroun...
متن کامل