Arthroscopic knots: determining the optimal balance of loop security and knot security.
نویسندگان
چکیده
PURPOSE The purpose of this study was to determine the optimal knot configuration that maximized both knot and loop security when tied with 2 different types of nonabsorbable, braided suture. TYPE OF STUDY In vitro biomechanical study. METHODS Six commonly used arthroscopic sliding knots (Duncan loop, Nicky's knot, Tennessee slider, Roeder knot, SMC knot, Weston knot) with and without a series of 3 reversing half-hitches on alternating posts (RHAPs) as well as a static surgeon's knot were tied. Two different nonabsorbable, braided sutures were used, and a total of 7 knots were tied for each possible combination of knots and sutures, for a total of 182 knots. Each knot was tied around a 30-mm circumference post to assure a consistent loop circumference of 30 mm before "locking" the complex sliding knots by tensioning the wrapping limb of the suture. Each loop was mounted on a Material Testing System machine, and its circumference was measured at a 5-N preload to assess each knot's ability to maintain a tight suture loop without slippage (loop security). Knot security was measured as the maximum force to failure at 3 mm of crosshead displacement or suture breakage during single-pull load testing. RESULTS The surgeon's knot provided the highest force to failure and the tightest loop circumference whether tied with No. 2 Ethibond (Ethicon, Somerville, NJ) or No. 2 Fiberwire (Arthrex, Naples, FL) suture. Among the sliding knots, the Roeder knot with 3 RHAPs showed the best balance of loop security and knot security when tied with No. 2 Ethibond or No. 2 Fiberwire. Sliding knots tied without RHAPs showed low force to failure and loose suture loops whether tied with Ethibond or Fiberwire. The addition of 3 RHAPs improved knot security and, in most cases, loop security of all the sliding knots. When tying a static surgeon's knot or a sliding knot with RHAPs, using No. 2 Fiberwire increased the force to failure over comparable knots tied with No. 2 Ethibond. All knots failed by a combination of knot slippage and suture stretch. When using No. 2 Ethibond, securing most sliding knots with 3 RHAPs or tying a surgeon's knot changed the failure mechanism from knot slippage to suture stretch, suggesting that the maximum knot holding capacity of No. 2 Ethibond had been achieved when tying these knot configurations. However, even at failure forces twice that achieved with No. 2 Ethibond, suture slippage continued to occur with sliding knots with 3 RHAPs using No. 2 Fiberwire. This indicates that the maximum knot-holding capacity of No. 2 Fiberwire had not been achieved, and that further knot configurations should be tested. CONCLUSIONS (1) A static surgeon's knot provides the best balance of loop security and knot security within the knot configurations tested in this study. (2) A sliding knot without RHAPs has both poor loop security and knot security and should not be tied. (3) The addition of 3 RHAPs improves knot security of all sliding knots tested and improves loop security of most of the sliding knots tested. (4) The addition of 3 RHAPs improves the knot security of all sliding knots to adequately resist predicted in vivo loads. (5) The Roeder knot with 3 RHAPs provides the best balance of loop security and knot security within the sliding knot configurations tested in this study regardless of suture type. (6) Tying a surgeon's knot or a sliding knot with 3 RHAPS using No. 2 Fiberwire increases knot security over the same knot tied with No. 2 Ethibond. CLINICAL RELEVANCE This study identifies the static and sliding configurations of commonly used arthroscopic knots in order to aid the surgeon in choosing the most biomechanically effective knot for use in arthroscopic surgery.
منابع مشابه
Initial loop and knot security of arthroscopic knots using high-strength sutures.
PURPOSE There are many options for arthroscopic knots including the type of knot and suture material used. The current investigation evaluated knot properties using 3 high-strength suture materials tied in 5 common arthroscopic knot configurations. METHODS Four arthroscopic sliding knots including the Roeder, Weston, SMC, and Tennessee Slider and an arthroscopic nonsliding Surgeon's knot were...
متن کاملBiomechanical comparison of four sliding knots and three high-strength sutures: Loop security is much different between each combination.
There are many types of sliding knots and suture materials used in arthroscopic surgery. The purposes of this study are (i) to evaluate the loop security of standard sliding knots when using different types of high-strength suture materials and (ii) to compare the loop security of a new sliding knot (Chula knot) to other standard sliding knots. Four configurations of sliding locking knots (West...
متن کاملThe modified racking hitch(MRH) knot: a new sliding knot for arthroscopic surgery.
Sliding knots are commonly used in arthroscopic surgery and can be problematic in terms of strength and loop security. A new sliding knot for arthroscopic surgery, a modified racking hitch (MRH) knot, is described. The knot is essentially a modified cow's hitch knot that includes two self-locking loops. By tensioning the loop strands, a snug knot is created without backward sliding and provides...
متن کاملValidation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity
Introduction With arthroscopic techniques being used, the importance of knot tying has been examined. Previous literature has examined the use of reversing half-hitches on alternating posts (RHAPs) on knot security. Separately, there has been research regarding different suture materials commonly used in the operating room. The specific aim of this study was to validate the effect of different ...
متن کاملPerformance Comparison of a Pretied Suture Knot With Three Conventional Arthroscopic Knots.
PURPOSE To compare the knot characteristics of a pretied suture knot with 3 of the most commonly used arthroscopic knots tied with various high-strength sutures. METHODS Three commonly used arthroscopic knots (surgeon's knot, Seoul Medical Center, and Duncan loop) tied with no. 2 high-strength sutures were compared with a pretied knot secured with either 1, 2, or 3 reversed half hitches (RHAP...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
دوره 20 5 شماره
صفحات -
تاریخ انتشار 2004