An LC-MS method for determination of milbemycin oxime in dog plasma.

نویسندگان

  • Qianqian Xu
  • Jichang Li
  • Zhiqiang Shen
  • Shijin Guo
  • Yubo Wang
  • Feng Li
چکیده

An HPLC-MS method has been developed and validated for the quantitative determination of milbemycin oxime (MBO) in dog plasma. The developed method has been then applied in in vivo clinical studies to obtain pharmacokinetics of MBO in blood after its oral administration. Samples were extracted using solid-phase extraction (SPE). Sample proteins were precipitated with acetonitrile (ACN) and sodium chloride (NaCl) and then diluted with methanol and water. Calibration standards were prepared by using plasma matrix and following the same SPE procedure. Chromatographic separation was performed on a Waters C18 packed column (3.5 μm particles diameter; 3 × 100 mm) with a C18 guard column (3.5 μm particles diameter; 3 × 20 mm). The mobile phase was an 85:15 (v/v) mixed solution of ACN and 5 mM ammonium acetate. The calibration curve was linear over a concentration range of 2.0-500 ng/mL with a limit of quantitation of 2.0 ng/mL. The oral administration of a pellet of 2.5 mg MBO produced blood concentrations ranging from 6.10 ± 0.92 to 78.81 ± 4.38 ng/mL within 6 h, with a terminal half-time of 11.66 ± 0.93 h. This study determined the suitability of the herein proposed method to investigate the pharmacokinetics of MBO after oral administration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of E. boehmi infection in a mixed-breed dog using milbemycin oxime.

Numerous bipolar plugged capillarid eggs were detected on a routine centrifugal fecal flotation examination of a 2 yr old castrated male boxer-Chinese shar pei mixed-breed. The eggs were identified as Eucoleus boehmi (E. boehmi), the nasal capillarid, based on size and shell wall surface morphology. The dog had a history of chronic sneezing (> 5 times/day) and intermittent postexercise nasal di...

متن کامل

Method validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.

Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...

متن کامل

A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...

متن کامل

Development and Application of a Validated Liquid Chromatography-Mass Spectrometry Method for the Determination of Dexchlorpheniramine Maleate in Human Plasma

     A convenient liquid chromatographic-single Quadrupole mass spectrometric (LC-MS) method was developed and validated for dexchlorpheniramine maleate (INN name: chlorphenamine) determination in human plasma. The need for just a single liquid-liquid extraction with ethyl acetate and being highly sensitive were the advantages of this method. The linearity was also excellent over the range of 1...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 52 9  شماره 

صفحات  -

تاریخ انتشار 2014