Comparison of in-the-ear and over-the-ear hearing aid fittings.

نویسندگان

  • R M Cox
  • D M Risberg
چکیده

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conformity of the real-ear aided response with the target response from the DSL v5 formula

Objectives: Real ear measurement plays a critical role in children’s hearing aid fitting. This study aimed to evaluate the conformity of measured and predicted real-ear aided response (REAR) of prescribed formula desired sensation level (DSL) v5 Pediatric in children aged 4 to 7 years. Since there is limited information about the effect of the degree of hearing loss (DOHL), ethnicity, gender, a...

متن کامل

Evaluation of an in-situ output probe-microphone method for hearing aid fitting verification.

Several hearing aid prescription procedures specify frequency gain functions in terms of the desired levels of amplified speech. The most direct method for verifying hearing aid fittings based on these procedures requires a measurement of amplified speech in the ear canal. This paper describes the evaluation of a probe microphone measurement procedure designed to measure amplified speech to ver...

متن کامل

Case Report of Unusual complications after hearing aid fitting that required surgical management

The making of ear mould for hearing aids is generally considered to be a safe process. However, there are a few reported cases of complications caused during mould making. We report the case of a man with 69 years age, where the process of making the mould for a hearing aid led to the perforation of the tympanic membrane and pouring of mould material into the middle ear, necessitating surgical ...

متن کامل

Effect of Suctioning of the Middle Ear Effusion on Hearing Condition Before Ventilation Tube Insertion

Abstract OME is a Common disease in children. over than 90% of children in preschool ages experienced this disease once at least. Despite medical therapy about 10% of the OME patients won't improved and these are the group of patients who referred to as chronic OME patients. Insertion of VT in TM is an accepted therapy for these patients and during surgery for insertion of VT, suctioning of mi...

متن کامل

Onset of auditory deprivation.

The purpose of this investigation was to study further the assertion that auditory function deteriorates in the unaided ear of individuals with sensorineural hearing loss (SNHL) who receive monaural hearing aid fittings. The word recognition scores (WRSs) of 77 monaurally and 65 binaurally fitted subjects with symmetric bilateral SNHL were examined at 1, 3, and 5 years post hearing aid fitting....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of speech and hearing disorders

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 1986