Heat Transfer and Friction Factor Study for Triangular Duct Solar Air Heater Having Discrete V-Shaped Ribs
ثبت نشده
چکیده
Solar energy is a good option among renewable energy resources due to its easy availability and abundance. The simplest and most efficient way to utilize solar energy is to convert it into thermal energy and this can be done with the help of solar collectors. The thermal performance of such collectors is poor due to less heat transfer from the collector surface to air. In this work, experimental investigations of single pass solar air heater having triangular duct and provided with roughness element on the underside of the absorber plate. V-shaped ribs are used for investigation having three different values of relative roughness pitch (p/e) ranges from 416 for a fixed value of angle of attack (), relative roughness height (e/Dh) and a relative gap distance (d/x) values are 60, 0.044 and 0.60 respectively. Result shows that considerable augmentation in heat transfer has been obtained by providing roughness. Keywords—Artificial roughness, Solar Air heater, Triangular duct, V-Shaped Ribs.
منابع مشابه
Spectrally selective ultra-high temperature ceramic absorbers for high- temperature solar plants
Related Articles Heat transfer and friction factor of solar air heater having duct roughened artificially with discrete multiple v-ribs J. Renewable Sustainable Energy 4, 033103 (2012) Heat transfer and friction characteristics of dimple-shaped roughness element arranged in angular fashion (arc) on the absorber plate of solar air heater J. Renewable Sustainable Energy 4, 023112 (2012) Experimen...
متن کاملCFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater
CFD analysis of 2-dimensional artificially roughened solar air heater duct with additional circular vortex generator, inserted in inlet section is carried out. Circular transverse ribs on the absorber plate are placed as usual. The analysis is done to investigate the effect of inserting additional vortex generator on the heat transfer and flow friction characteristics inside the solar air heate...
متن کاملInvestigating The Parameters For The Performance Enhancement Of A Solar Air Heater Having Different Artificially Roughened Geometries
The use of an artificial roughness on a surface of absorber plate is an effective technique to enhance the rate of heat transfer to fluid flow in the duct of a solar air heater. This paper presents a comparison of parameters that enhance the heat transfer coefficient thus efficiency ofa solar air heater for different artificially roughened geometries for the Reynolds number from 2500 -18000. Th...
متن کاملAnalysis of Heat Transfer Augmentation and Flow Characteristics due to Rib Roughness of a Solar Air Heater
This paper presents the study of fluid flow and heat transfer in a plain rectangular duct of a solar air heater by using Computational Fluid Dynamics (CFD). The effect of Reynolds number on heat transfer coefficient and friction factor was investigated. A commercial finite volume package ANSYS FLUENT 12.1 is used to analyze and visualize the nature of the flow across the duct of a solar air hea...
متن کاملCFD Analysis on the Thermal Hydraulic Performance of an SAH Duct with Multi V-Shape Roughened Ribs
Abstract: This study presents the heat transfer and fluid flow characteristics in a rib-roughened SAH (solar air heater) channel. The artificial roughness of the rectangular channel was in the form of a thin circular wire in discrete multi V-pattern rib geometries. The effect of this geometry on heat transfer, fluid flow, and performance augmentation was investigated using the CFD (computationa...
متن کامل