Transparency to Reduce Surgical Implant Waste
نویسندگان
چکیده
BACKGROUND Rising health care costs and emphasis on value have placed the onus of reducing healthcare costs on the surgeon. METHODS Financial data from 3,973 hip, knee, and shoulder arthroplasties performed at a physician owned orthopedic hospital was retrospectively reviewed over a two-year period. A wasted implant financial report was posted starting the second year of the study. Each surgeon's performance could be identified by his peers. RESULTS After posting of the financial report, 1.11% of all hip and knee arthroplasty cases had a waste event compared to 1.50% during the control year. Shoulder arthroplasty waste events occurred twice as often than that observed in hip and knee arthroplasty during the study period. A decrease in waste events was observed but was not statistically significant (p = 0.30). CONCLUSIONS Posting a non-blinded wasted implant data sheet was associated with a reduction in the number of wasted orthopedic surgical implants in this series, although the reduction was not statistically significant.
منابع مشابه
Orthopedic Implant Waste: Analysis and Quantification.
The steadily increasing demand for orthopedic surgeries and declining rates of reimbursement by Medicare and other insurance providers have led many hospitals to look for ways to control the cost of these surgeries. We reviewed administrative records for a 1-year period and recorded total number of surgical cases, number of cases in which an implant was wasted, and cost of each wasted implant. ...
متن کاملOperating room waste: disposable supply utilization in neurosurgical procedures.
OBJECTIVE Disposable supplies constitute a large portion of operating room (OR) costs and are often left over at the end of a surgical case. Despite financial and environmental implications of such waste, there has been little evaluation of OR supply utilization. The goal of this study was to quantify the utilization of disposable supplies and the costs associated with opened but unused items (...
متن کاملThe Effect of Surface Treatment on Corrosion behavior of Surgical 316L Stainless Steel Implant
The AISI 316 L Stainless Steel (SS) specimens were exposed to passivation surface through two different processes including; holding in 40-vol% HNO3 at temperature of 60 ºC for 30 min and 15-vol%H2SO4 at ambient temperature for 1 hour. The corrosion behavior of specimens was evaluated in physiological solutions by electrochemical in vitro tests through linear an...
متن کاملForced-Air Warming Discontinued: Periprosthetic Joint Infection Rates Drop
Several studies have shown that the waste heat from forced-air warming (FAW) escapes near the floor and warms the contaminated air resident near the floor. The waste heat then forms into convection currents that rise up and contaminate the sterile field above the surgical table. It has been shown that a single airborne bacterium can cause a periprosthetic joint infection (PJI) following joint r...
متن کاملCapsular Weakness around Breast Implant: A Non-Recognized Complication
Capsular contraction is a frequent complication following breast augmentation. On the other hand, capsular weakness, a not widely recognized complication, may occur around the implant. A weak capsule allows the migration of the prosthesis to the lateral region of the thoracic region or inferiorly, towards the abdomen, due to gravitational forces. The cause of capsular weakness remains unresolve...