Title: Analysis of Laser Ablation Plumes by Laser-Induced Breakdown Spectroscopy and Quadrupole Mass Spectrometry: a Preliminary Study

نویسندگان

  • J. S. Astin
  • R. D. Pilkington
  • A. E. Hill
  • M. Longson
  • T. Robinson
چکیده

Plasma plumes resulting from Nd:YAG laser ablation of copper and Fecralloy (Fe 72.8%, Cr 22%, Al 5%, Zr trace, Y trace) have been analysed simultaneously with Laser-Induced Breakdown Spectroscopy (LIBS) and Laser Ablation Mass Spectrometry (LAMS). A commercially available Residual Gas Analyser (RGA) was employed to perform mass spectrometric analysis of the neutral and ionic species created during the laser ablation process. Investigations of laser repetition rate have shown that increasing the frequency of the laser pulse rate is detrimental to the mass spectra produced; the average detectable partial pressure drops and the relative standard deviation of the signal increases. The RGA has been shown to be susceptible to corruption of measurement due to pump oil contamination when recording the partial pressure of neutral species created by the ablation event. Lack of 1 synchronisation between the transient laser pulse and the RGA mass scan results in variable partial pressure readings when analysing both neutral and ionic species. LAMS is able to detect small trace amounts of Zirconium and Yttrium in Fecralloy; LIBS is unable to resolve these trace amounts, but is shown to be unaffected by chamber pump oil contamination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and computational study of complex shockwave dynamics in laser ablation plumes in argon atmosphere

We investigated spatio-temporal evolution of ns laser ablation plumes at atmospheric pressure, a favored condition for laser-induced breakdown spectroscopy and laser-ablation inductively coupled plasma mass-spectrometry. The 1064 nm, 6 ns pulses from a Nd:YAG laser were focused on to an Al target and the generated plasma was allowed to expand in 1 atm Ar. The hydrodynamic expansion features wer...

متن کامل

The effect of self-absorption correction using internal reference on determining heavy metals concentration by laser induced breakdown spectroscopy

The identification and concentration of heavy metals, which may be so harmful for the body, is determined by the method of calibration-free laser-induced breakdown spectroscopy using a special strategy. First, the plasma temperature is obtained using the Boltzmann plot. Then, a line with an inappreciable self-absorption is considered for each element as the reference. The modified intensities o...

متن کامل

Spatially Resolved Laser Induced Breakdown Spectroscopy in Orthogonal Double Pulse Configuration and Laser Ablation Inductively Coupled Plasma Mass Spectrometry of Archaeological Findings

Local analysis of dental calcified tissues plays important role in medicine, toxicology, environmental science, paleontology and anthropology. In these fields of action a bulk analysis of a mineralized material from a defined and welllocalized volume belongs to a marginal stream. On the other hand, spatially resolved analyses of calcified tissues as teeth or bones without any previous decomposi...

متن کامل

Analysis of trace metals in comparison of laser-induced breakdown spectroscopy with LA-ICP-MS

Laser-induced breakdown spectroscopy (LIBS) and LA-ICP-MS (laser ablation inductively coupled plasma mass-spectrometry) were used for the detection of trace metals in a solid matrix consisting of KBr and two oxides. The results of both methods were compared to investigate the strengths and weaknesses of both methods. Most difficulties for quantification of LIBS data are related to matrix effect...

متن کامل

Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry

A hand-held diode laser is implemented for solid sampling in portable ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave battery-powered surgical laser diode is employed for portable laser diode thermal desorption (LDTD) at 940 nm and compared with nanosecond pulsed laser ablation at 2940 nm. Postionization is achieved in both cases using atmospheric pressure photoionization ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007