Design and Fabrication of Double-Focused Ultrasound Transducers to Achieve Tight Focusing
نویسندگان
چکیده
Beauty treatment for skin requires a high-intensity focused ultrasound (HIFU) transducer to generate coagulative necrosis in a small focal volume (e.g., 1 mm³) placed at a shallow depth (3-4.5 mm from the skin surface). For this, it is desirable to make the F-number as small as possible under the largest possible aperture in order to generate ultrasound energy high enough to induce tissue coagulation in such a small focal volume. However, satisfying both conditions at the same time is demanding. To meet the requirements, this paper, therefore, proposes a double-focusing technique, in which the aperture of an ultrasound transducer is spherically shaped for initial focusing and an acoustic lens is used to finally focus ultrasound on a target depth of treatment; it is possible to achieve the F-number of unity or less while keeping the aperture of a transducer as large as possible. In accordance with the proposed method, we designed and fabricated a 7-MHz double-focused ultrasound transducer. The experimental results demonstrated that the fabricated double-focused transducer had a focal length of 10.2 mm reduced from an initial focal length of 15.2 mm and, thus, the F-number changed from 1.52 to 1.02. Based on the results, we concluded that the proposed double-focusing method is suitable to decrease F-number while maintaining a large aperture size.
منابع مشابه
Piezoceramic Element Design and Fabrication for Ultrasonic Transducer of Gas Meter
Ultrasonic transducers play a significant role in generating and receiving the acoustic waves in ultrasonic flowmeters. Depending on the required accuracy, the ultrasonic transducers can be installed either in one pair or more in an ultrasonic flowmeter. The main part of an ultrasonic transducer is its piezoceramic element. In this work, four piezoceramic elements with different diameter to thi...
متن کاملProgress in Development of HIFU CMUTs for use under MR-guidance
High intensity focused ultrasound (HIFU) guided by magnetic resonance imaging (MRI) is a noninvasive treatment that potentially reduces patient morbidity, lowers costs, and increases treatment accessibility. Traditionally, piezoelectric transducers are used for HIFU, but capacitive micromachined ultrasonic transducers (CMUTs) have many advantages, including fabrication flexibility, low loss, an...
متن کاملUltrahigh Frequency (100 MHz–300 MHz) Ultrasonic Transducers for Optical Resolution Medical Imagining
High resolution ultrasonic imaging requires high frequency wide band ultrasonic transducers, which produce short pulses and highly focused beam. However, currently the frequency of ultrasonic transducers is limited to below 100 MHz, mainly because of the challenge in precise control of fabrication parameters. This paper reports the design, fabrication, and characterization of sensitive broadban...
متن کاملGenerating and Focusing the Ultrasound Waves Using Elastomer-based Capacitive Micro-Speakers
Ultrasound wave is a kind of waves with the frequency higher than the human audible frequency. Although ultrasound was first used for military identification purposes, it has been used for decades for various other applications, especially medical applications. Medical applications of ultrasound include diagnostic and therapeutic applications, such as for the treatment of cancer. In this paper,...
متن کاملFocused ultrasound in ophthalmology
The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, m...
متن کامل