Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power
نویسندگان
چکیده
PURPOSE To determine whether the total corneal refractive power (TCRP) value, which is based on measurement of both anterior and posterior corneal astigmatism, is effective for toric intraocular lens (IOL) calculation with AcrySof(®) Toric IOLs. PATIENTS AND METHODS A consecutive series of cataract surgery cases with AcrySof toric IOL implantation was studied retrospectively. The IOLMaster(®) was used for calculation of IOL sphere, the Pentacam(®) TCRP 3.0 mm apex/ring value was used as the keratometry input to the AcrySof Toric IOL Calculator and the VERION™ Digital Marker for surgical orientation. The keratometry readings from the VERION reference unit were recorded but not used in the actual calculation. Vector differences between expected and actual residual refractive cylinder were calculated and compared to simulated vector errors using the collected VERION keratometry data. RESULTS In total, 83 eyes of 56 patients were analyzed. Residual refractive cylinder was 0.25 D or lower in 58% of eyes and 0.5 D or lower in 80% of eyes. The TCRP-based calculation resulted in a statistically significantly lower vector error (P<0.01) and significantly more eyes with a vector error ≤0.5 D relative to the VERION-based calculation (P=0.02). The TCRP and VERION keratometry readings suggested a different IOL toric power in 53/83 eyes. In these 53 eyes the TCRP vector error was lower in 28 cases, the VERION error was lower in five cases, and the error was equal in 20 cases. When the anterior cornea had with-the-rule astigmatism, the VERION was more likely to suggest a higher toric power and when the anterior cornea had against-the-rule astigmatism, the VERION was less likely to suggest a higher toric power. CONCLUSION Using the TCRP keratometry measurement in the AcrySof toric calculator may improve overall postoperative refractive results. Consideration of measured posterior corneal astigmatism, rather than a population-averaged value, appears advantageous.
منابع مشابه
Toric intraocular lens outcome using the manufacturer's prediction of corneal plane equivalent intraocular lens cylinder power.
OBJECTIVES To describe the refractive outcome of toric intraocular lens (IOL) implantation by comparing the postoperative refractive astigmatism with the preoperative keratometric astigmatism target. METHOD In a university department of a publicly funded hospital, 38 eyes of 29 patients underwent routine cataract surgery with insertion of a toric implant (SN60TT AcrySof Toric). Surgically ind...
متن کاملRefractive surprise after toric intraocular lens implantation: graph analysis.
PURPOSE To determine the refractive cylinder effect of rotating a toric intraocular lens (IOL) and identify the sources of refractive astigmatic surprise after toric IOL implantation. SETTING Private practice, Melbourne, Australia. DESIGN Experimental study. METHODS Vergence formulas using a standard reduced eye model were used to bring all lens powers to the corneal plane. Double-angle v...
متن کاملAssessing the Likely Effect of Posterior Corneal Curvature on Toric IOL Calculation for IOLs of 2.50 D or Greater Cylinder Power.
PURPOSE To establish whether average refractive overcorrection or undercorrection of corneal astigmatism based on the orientation (rule) of the astigmatism occurs if toric intraocular lenses (IOLs) are calculated on the basis of anterior corneal measurements in eyes requiring toric IOL cylinder power of 2.50 diopters (D) or greater. METHODS One hundred thirteen consecutive eyes with anterior ...
متن کاملCorneal topographic astigmatism (CorT) to quantify total corneal astigmatism.
PURPOSE To evaluate the performance of corneal topographic astigmatism (CorT) based on total corneal power measurements. METHODS Anterior, posterior, and total corneal power measurements of 526 virgin eyes obtained using the CSO Sirius tomographer (Costuzione Strumenti Oftalmici, Scandicci, Florence, Italy) were analyzed. Individual CorTs were created from each set of data. These CorTs were a...
متن کاملComparison of Two Toric IOL Calculation Methods
Purpose To compare two calculators for toric intraocular lens (IOL) calculation and to evaluate the prediction of refractive outcome. Methods Sixty-four eyes of forty-five patients underwent cataract surgery followed by implantation of a toric intraocular lens (Zeiss Torbi 709 M) calculated by a standard industry calculator using front keratometry values. Prediction error, median absolute err...