Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions.
نویسندگان
چکیده
BACKGROUND Previous studies found contradictory results regarding the question whether mixed venous oxygen saturation (Svo2) and central venous oxygen saturation (Scvo2) are equivalent. The inconsistency of study results may result from different study designs and different, partly questionable, statistical approaches. METHODS The authors performed a prospective clinical trial comparing individual oxygen saturation values as well as the trend of values in blood from the superior vena cava (Scvo2), the right atrium (Srao2), and the pulmonary artery (Svo2) during varying hemodynamic situations. The subjects were 70 patients scheduled to undergo elective neurosurgical operations in the sitting position. Oxygen saturation was measured photospectrometrically in blood samples simultaneously taken at four different time points during supine and sitting positions. Statistical analysis was performed following the recommendations of Bland and Altman. RESULTS Five hundred two comparative sets of measurements were obtained. Ninety-five percent limits of agreement ranging from +/-6.83 to +/-9.30% for single values were interpreted as clinically unacceptable. In contrast, correlations between changes of Svo2 and Scvo2 as well as of Svo2 and Srao2 were interpreted as clinically acceptable (R > or = 0.755, Pearson correlation coefficient; P < or = 0.0001). CONCLUSIONS In this sample of patients, exact numerical values of Scvo2 and Srao2 are not equivalent to those of Svo2 in varying hemodynamic conditions. However, for clinical purposes, the trend of Scvo2 may be substituted for the trend of Svo2. In addition, previous studies investigating the agreement between Svo2 and Scvo2 were found to be lacking in their chosen statistical approaches.
منابع مشابه
Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand.
Because central venous O2 saturation (superior vena cava, ScvO2) can be monitored with less patient risk than mixed venous O2 saturation (pulmonary artery, SvO2), we examined the correlations between SvO2 and ScvO2 over a broad range of cardiorespiratory conditions, including hypoxia, hemorrhage, and resuscitation in anesthetized dogs. The correlation coefficient (r) between SvO2 and ScvO2 in 1...
متن کاملCorrelation of mixed venous and central venous oxygen saturation and its relation to cardiac index
Background and Aim: The clinical applicability of substitution of central venous oxygen saturation for mixed venous oxygen saturations in monitoring global tissue hypoxia is still a matter of controversy. Hence aim of the study is comparison of paired samples of mixed venous and central venous oxygen saturation and comparison in relation to cardiac index in varying hemodynamic conditio s. Mater...
متن کاملCritical Assessment of Use of Central Venous Oxygen Saturation as a Mirror of Mixed Venous Oxygen in Severely Ill Cardiac Patients By MELVIN
Bedside catheterization of the right heart with a percutaneously introduced flowdirected catheter was carried out in 24 critically ill patients; 71 determinations of mixed venous oxygen saturation (MVo2) were obtained. A second catheter was inserted either into a central intrathoracic vein or the right atrium for simultaneous sampling of central venous (CVo2) or right atrial (RAo2) oxygen satur...
متن کاملVenous oximetry
Tissue hypoxia is the central pathophysiological process in shock and an important co-factor in the development of organ dysfunction. Hemodynamic parameters, usually used to assess the perfusion of organs and tissues, like arterial blood pressure, heart rate, urine output and blood gases can be normal in the presence of tissue hypoxia and cannot rule out imbalances between global oxygen supply ...
متن کاملValidity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content
Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 103 2 شماره
صفحات -
تاریخ انتشار 2005