pH Dependence and Unsuitability of Fluorescein Dye as a Tracer for Pesticide Mobility Studies in Acid Soil
نویسنده
چکیده
The mobility of fluorescein and bromide used as tracers in packed soil columns was investigated. Five different soils were used in two application methods: soil surface application and soil incorporation, both of which simulate accepted methods of soil application of termiticides to prevent structural infestation. The breakthrough of bromide and fluorescein in column eluates were measured. The absorbance of fluorescein at 492 nm was pH dependent, and proper adjustments were made after measuring the eluate pH. Although high recoveries of bromide from the soil columns were observed, the breakthrough was different among the soil types, indicating that bromide behaves differently in different soils. Recovery of fluorescein, a weak acid, varied depending upon the pH of the soil used, and was only observed in the eluates of two of the five soils tested. Soil treated with bromide and fluorescein followed by soaking extraction showed high recovery of bromide but low recovery of fluorescein, except for in the most alkaline of the soils tested. If fluorescein is used as a conservative tracer in pesticide soil mobility studies, mobility can be underestimated in acidic soils because the active ingredient might travel more quickly than does the fluorescein.
منابع مشابه
Fabrication of Nanoporous Functionalized Hydroxyapatite as High Performance Adsorbent for Acid Blue 25 Dye Removal
In this study, nanoporous hydroxyapatite was synthesized and functionalized via tetraethylenepentamine in order to obtain a novel adsorbent for efficient removal of Acid Blue 25 dye from aqueous solution. Functionalized hydroxyapatite was characterized by Fourier transform infrared spectroscopy (FTIR), X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (...
متن کاملFluorescent Intensity of Dye Solutions under Different pH Conditions
Fluorescent tracers are widely used for assessment of spray quantity in the field due to their relatively high sensitivity, low cost and user safety. However, many concerns have been raised over their measurement accuracy due to questions of stability of fluorescence during tests. Stable analysis of fluorescence is essential to ensure accurate evaluation of pesticide spray application efficienc...
متن کاملMeasuring thermodynamic details of DNA hybridization using fluorescence
Modern real-time PCR systems make it easy to monitor fluorescence while temperature is varied for hundreds of samples in parallel, permitting high-throughput studies. We employed such system to investigate melting transitions of ordered nucleic acid structures into disordered random coils. Fluorescent dye and quencher were attached to oligonucleotides in such a way that changes of fluorescence ...
متن کاملRemoval of Acid Red 14 by Pumice Stone as a Low Cost Adsorbent: Kinetic and Equilibrium Study
In this work, removal of C. I. Acid Red 14 was investigated by Pumice stone as a low cost adsorbent. Various parameters such as initial dye solution, contact time and pH were studied. Removal of dye were increased by increasing of contact time and initial dye solution and deceased by increasing of pH. Three isotherm models were studied. Linear and non-linear regression analyses were used fo...
متن کاملEquilibrium and Thermodynamics Studies for Decolorization of Reactive Black 5 by Adsorption onto Acid Modified Banana Leaf Ash
Abstract Background: At present study, acid modified banana leaf ash was used as an adsorbent for the successful removal of Reactive Black 5 (RB5) dye from aqueous environments. Materials and methods: The effect of various operating parameters such as pH of solution, dye concentration, contact time, adsorbent dosage, and the temperature was investigated. Results: Maximum adsorption capacity of ...
متن کامل