CMS NOTE 1997 / 003 CMS Note

نویسنده

  • P. Vitulo
چکیده

Abstract A 2 mm gas gap Resistive Plate Chamber with bakelite plates has been operated in avalanche mode under a 137Cs source irradiation. We report on measurements of the efficiency in cosmic rays detection and of the charge developed in the gap, performed for two different gas mixtures: the first containing a high percentage of environmental friendly ”freon” C2H2F4; the second one having a high percentage of argon. We show that the freon based mixture exhibits a wide full efficiency plateau with low streamer probability, whilethe argon based mixture allows to reduce the detector power consumption.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detector Construction Management and Quality Control: Establishing and Using a CRISTAL System

J.-M. Le Goff CERN, Geneva, Switzerland G. Chevenier1 Institut fur Teilchenphysik, Eidgenossische Technische Hochschule, Zurich, Switzerland A. Bazan, T. Le Flour, S. Lieunard, S. Murray, J.-P.Vialle LAPP, IN2P3, Annecy-le-Vieux, France N. Baker, F. Estrella1, Z. Kovacs1, R. McClatchey1 Dept. of Computing, Univ. West of England, Frenchay, Bristol BS16 1QY UK G. Organtini Universita di Roma e Se...

متن کامل

Principles of the cutting method proposed for the PbWO4 crystals of the CMS Electromagnetic Calorimeter

A method for cutting the 110’000 PbWO4 crystals of the CMS Electromagnetic Calorimeter is proposed. The machinery, the tooling and the sequence of operation are described. Processing parameters resulting from experimental runs are indicated. A mass production organisation is forecasted. CMS Note 1997/024 01 04 1997 M. Lebeau 2

متن کامل

on CMS information server CMS NOTE 1997 / 004 CMS Note The Compact Muon Solenoid Experiment

Some properties of a 90% C2H2F4 gas mixture, used to operate resistive plate chambers in avalanche mode, are determined by comparing the experimental results with the prediction of simple analytical calculations. The fast charge distribution of the signal induced on pick-up electrodes is reproduced by means of a Monte Carlo simulation of the avalanche development. In addition predictions for a ...

متن کامل

CMS information server CMS NOTE 1997 / 043 CMS Note The Compact

The effect of external as well as internal bremsstrahlung radiation in H ! ZZ ! 4e channel is studied in full detector simulation. A method is proposed for external and internal bremsstrahlung recovery, allowing us to use 95% of electrons within j E=pgen 1 j 0.2. It is shown that traditional E=p and isolation cuts can be implemented with 90% efficiency, but that precise mass reconstruction is a...

متن کامل

Signal-to-Noise Evaluations for the CMS Silicon Microstrip Detectors

This note gathers the existing information on the parameters of the CMS silicon microstrip detectors, in order to compute the signal–to–noise ratio for different configurations. Both signal and noise are computed analytically, starting from laboratory measurements of the characteristic impedances of the detectors. Results are presented for a 50 m strip pitch detector, read out every strip and e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007