Effects of iodinated contrast and field strength on gadolinium enhancement: implications for direct MR arthrography.

نویسندگان

  • Douglas D Montgomery
  • William B Morrison
  • Mark E Schweitzer
  • Dominik Weishaupt
  • Lawrence Dougherty
چکیده

PURPOSE To optimize direct magnetic resonance (MR) arthrography by determining the effect of dilution of gadolinium in iodinated contrast, saline, or albumin on T1-weighted, T2-weighted, and gradient-recalled echo (GRE) images, and the effect of scanner field strength. MATERIALS AND METHODS Gadopentetate dimeglumine was diluted into normal saline, albumin, or iodinated contrast (0.625 mmol/liter to 40 mmol/liter). Samples were scanned at 1.5T and 0.2T. Signal intensity was measured using T1-weighted spin-echo (SE), T2-weighted SE, and two- and three-dimensional GRE (20 degrees-75 degrees flip angle) sequences. Graphical analysis of signal intensity vs. gadolinium concentration was performed. RESULTS Albumin had no effect on gadolinium contrast. Dilution of gadolinium in iodinated contrast decreased signal intensity on all sequences compared to samples of identical concentration diluted in saline at both 1.5T and 0.2T: with a 2 mmol/liter gadolinium solution at 1.5T, signal was decreased by 26.1% on T1-weighted images, 31.7% on GRE20 images, and 28.9% on GRE45 images, and the T2 value decreased by 71.1%; at 0.2T, signal was decreased by 23.5% on T1-weighted images. On all sequences, the peak signal shifted to the left (lower gadolinium concentration) when diluted in iodinated contrast. Peak signal was also seen at different gadolinium concentrations on different sequences and field strength: at 1.5T, peak in saline/iodine was 2.5/0.625 mmol/liter on T1-weighted images, and 2.5/1.25 mmol/liter on GRE20 and GRE45 sequences. At 0.2T, peak in saline/iodine was 0.625-2.5/1.25 mmol/liter on T1-weighted images, 0.625-2.5/1.25 on GRE45 images, 2.5-10.0/1.25-5.0 mmol/liter on GRE65 images, and 1.25-5.0/0.625-1.25 mmol/liter on GRE75 images. CONCLUSION Dilution of gadolinium in iodinated contrast results in decreased signal on T1-weighted, T2-weighted, and GRE images compared to dilution in saline or albuminfor both 1.5-T and 0.2-T scanners; if gadolinium is diluted in iodinated contrast for MR arthrography, a lower concentration should be used because the peak is shifted to the left. The use of iodinated contrast should be minimized, as it may diminish enhancement and lower the sensitivity and specificity of MR arthrography. Optimal gadolinium concentration for MR arthrography is dependent on scanner field strength and a broader range of gadolinium concentration can be used to provide maximal signal at low field strength.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of the Contrast Mixture Ratio for Simultaneous Direct MR and CT Arthrography: an in Vitro Study

OBJECTIVE This study was designed to determine the optimal mixture ratio of gadolinium and iodinated contrast agent for simultaneous direct MR arthrography and CT arthrography. MATERIALS AND METHODS An in vitro study was performed utilizing mixtures of gadolinium at six different concentrations (0.625, 1.25, 2.5, 5.0, 10 and 20 mmol/L) and iodinated contrast agent at seven different concentra...

متن کامل

Quantification of the Relaxation Times of Combined CT and MR Contrast Agents for Optimal Imaging at MR Arthrography

Introduction Using both iodinated X-ray contrast and gadolinium (Gd) based MR contrast agents is helpful when performing MR arthrography. Joint visualization is enhanced if fluoroscopy is used for needle placement and a CT exam can be performed without an additional needle stick if the MR arthrogram is unsuccessful. However, the presence of iodinated contrast alters the relaxivity of gadolinium...

متن کامل

Effects of adding local anesthetic and iodinated contrast agents to the paramagnetic contrast solution in direct MR arthrography

Radiol Bras. 2015 Mar/Abr;48(2):V–VI The introduction of hardware and software innovations have resulted in a huge advance for diagnostic imaging in the last decades, especially the evolution of functional studies of human tissues which do not require the use of contrast medium. Nevertheless, the use of contrast agents is still required in specific settings of the clinical practice to different...

متن کامل

Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study*

OBJECTIVE To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. MATERIALS AND METHODS Samples specially prepared for the study with three different concentrations of paramagnetic co...

متن کامل

Field-Strength Dependence of Gadolinium Enhancement: Theory and Implications

The decision to use contrast in magnetic resonance (MR) examination has important diagnostic , economic, and medicolegal implications. The overwhelming majority of published studies defining the clinical utility of gadolinium administration for neuroimaging have been performed at high fields (1-6) . Are these conclusions about contrast agent use at high fields equally valid for low-field imagin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 2002