Pulsatile venous waveform quality affects the conduit performance in functional and "failing" Fontan circulations.
نویسندگان
چکیده
OBJECTIVE To investigate the effect of pulsatility of venous flow waveform in the inferior and superior caval vessels on the performance of functional and "failing" Fontan patients based on two primary performance measures - the conduit power loss and the distribution of inferior caval flow (hepatic factors) to the lungs. METHODS Doppler angiography flows were acquired from two typical extra-cardiac conduit "failing" Fontan patients, aged 13 and 25 years, with ventricle dysfunction. Using computational fluid dynamics, haemodynamic efficiencies of "failing", functional, and in vitro-generated mechanically assisted venous flow waveforms were evaluated inside an idealised total cavopulmonary connection with a caval offset. To investigate the effect of venous pulsatility alone, cardiac output was normalised to 3 litres per minute in all cases. To quantify the pulsatile behaviour of venous flows, two new performance indices were suggested. RESULTS Variations in the pulsatile content of venous waveforms altered the conduit efficiency notably. High-frequency and low-amplitude oscillations lowered the pulsatile component of the power losses in "failing" Fontan flow waveforms. Owing to the offset geometry, hepatic flow distribution depended strongly on the ratio of time-dependent caval flows and the pulsatility content rather than mixing at the junction. "Failing" Fontan flow waveforms exhibited less balanced hepatic flow distribution to lungs. CONCLUSIONS The haemodynamic efficiency of single-ventricle circulation depends strongly on the pulsatility of venous flow waveforms. The proposed performance indices can be calculated easily in the clinical setting in efforts to better quantify the energy efficiency of Fontan venous waveforms in pulsatile settings.
منابع مشابه
نتایج جراحی فونتان بدون استفاده از ماشین قلب و ریه در 41 بیمار
Background: The Fontan operation is the definitive operation for palliation of complex congenital heart disease with single –ventricle physiology. The use of the extra cardiac conduit has recently been gaining popularity. The purpose of this study was to compare the outcomes of extra cardiac conduit Fontan procedure (off-pump technique) and that of traditional technique (lateral tunnel techniqu...
متن کاملIs the extracardiac conduit the preferred Fontan approach for patients with univentricular hearts? The extracardiac conduit is not the preferred Fontan approach for patients with univentricular hearts.
There is, perhaps, no disease entity that better exemplifies the complexities, challenges, and creative innovations characteristic of the evolution in congenital heart disease care than the univentricular heart. The univentricular heart encompasses an array of uncommon and severe inborn cardiac malformations that share a similar physiology, with pulmonary and systemic venous return predominantl...
متن کاملChanges in venous return parameters associated with univentricular Fontan circulations.
To clarify the physiology of venous return (Q(vr)) in Fontan circulations, venous return conductance (G(vr)) and mean circulatory filling pressure (P(mcf)) were determined in pentobarbital sodium-anesthetized pigs. Relationships between Q(vr) and right (biventricular, n = 8) or left (Fontan, n = 8) filling pressures are described by straight lines with significant correlation coefficients. Esti...
متن کاملIs the extracardiac conduit the preferred Fontan approach for patients with univentricular hearts? The extracardiac conduit is the preferred Fontan approach for patients with univentricular hearts.
Fontan palliation for single-ventricle patients was first described in 1971.1 The original approach was in the form of a classic atriopulmonary Fontan connection, bypassing the nonfunctional right ventricle. After recognizing the long-term complication of an atriopulmonary connection (right atrial dilation, arrhythmias, and thrombus formation), modifications have been made. The atriopulmonary c...
متن کاملManagement of the failing Fontan circulation
The ‘Fontan circulation’ has evolved to include a variety of surgical procedures designed to overcome the absence of two distinct ventricular chambers. w1ew3 Inherent to this circulation is chronic elevation of right atrial and vena caval pressure, and absence of a dedicated power source to serve the pulmonary circulation, making low pulmonary vascular resistance and optimal systemic ventricula...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiology in the young
دوره 22 3 شماره
صفحات -
تاریخ انتشار 2012